Evidence map›Paper›PMID 39227854›Full record

ArticleBMC ophthalmology2024

Thiel cadaver eye as a training model for sub-Tenon's blocks: a feasibility study.

Friedrich Lersch, Damian Schnidrig, Susanne Boemke, Valentin Djonov, Damian Jaggi, Florian M Heussen

Abstract read
In one paragraph

Article in BMC ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Friedrich LerschDepartment of Anaesthesiology, Inselspital, University Hospital Bern, Bern, 3010, Switzerland. friedrich.lersch@insel.ch.
Damian SchnidrigHaag-Streit AG Diagnostics, Köniz, Switzerland.
Susanne BoemkeInstitute of Anatomy, University of Bern, Bern, Switzerland.
Valentin DjonovInstitute of Anatomy, University of Bern, Bern, Switzerland.
Damian JaggiDepartment of Ophthalmology, Inselspital, University Hospital Bern, Bern, Switzerland.
Florian M HeussenDepartment of Ophthalmology, Inselspital, University Hospital Bern, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRegional anaesthesia education, especially for ocular procedures, necessitates reliable surgical training models. While cadaveric models offer anatomical fidelity, conventional embalming methods may compromise tissue integrity. We aimed to assess the effectiveness of Thiel cadavers for training in sub-Tenon's blocks by evaluating ocular tissues and measuring insertion forces.

methodsExperimental design, using twenty eyes from ten Thiel cadaver heads. These cadavers were specifically prepared to test the administration of sub-Tenon's blocks. The research was conducted in a controlled laboratory setting appropriate for handling cadaveric materials and conducting precise measurements. Each cadaver eye underwent an initial ultrasound examination, and its axial length was noted. An intravitreal injection of heptastarch solution followed, to re-establish the eye's sphericity. After this volume injection, the axial length and intraocular pressure were measured again. Mock sub-Tenon's blocks were administered in 2 separate quadrants of the eye, with insertion forces measured using a pressure gauge. These were compared to a data set of insertion forces measured in a series of isolated pig's eyes on which STBs had been performed. Main outcome measurements were macroscopic assessment of the ocular tissue layers and the insertion forces required for the sub-Tenon's blocks. In a second set of 10 Thiel cadaver heads, 5 ml of sodium chloride were injected as sub-Tenon's blocks and the emergence of a periocular "T-sign" ascertained and measured by ultrasound.

resultsFour of twenty eyes (20%) retained near-natural sphericity, with the remaining requiring volume injection to approximate physiological shape and pressure. The conjunctiva and Tenon's layer were intact, and correct cannula placement was achieved in all cases. In 16 of 20 eyes where T-signs could be measured, the median thickness of the T-sign amounted to 2.72 mm (range 1.34 mm-5.28 mm). The average maximum cannula insertion force was 2.92 Newtons. Insertion forces in intact Thiel cadaver heads were consistently higher than in isolated pig's eyes (3.6 N vs 2.0 N).

conclusionThese findings suggest that Thiel cadavers are a promising model for training in sub-Tenon'sblocks, despite the challenge of often desiccated and involuted eyes.

Indexed as

CadaverFeasibility StudiesAnimalsHumansIntraocular PressureNerve BlockOphthalmologySwineTenon CapsuleCadaverLocal anaesthesiaSimulation trainingTenon’ capsule

Identifiers

PMID39227854
PMCPMC11370276

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.