Evidence map›Paper›PMID 39227657›Full record

Trial reportScientific reports2024

Randomized crossover trial of a demand oxygen delivery system in nocturnal hypoxemia.

Atsuhiko Yatani, Tatsuya Nagano, Sae Murakami, Takehiro Otoshi, Daisuke Hazama, Naoko Katsurada, Masatsugu Yamamoto, Motoko Tachihara, Yoshihiro Nishimura, Kazuyuki Kobayashi

Abstract readRandomized Controlled TrialEquivalence Trial
In one paragraph

Trial report in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Atsuhiko YataniDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Tatsuya NaganoDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan. tnagano@med.kobe-u.ac.jp.
Sae MurakamiClinical and Translational Research Center, Kobe University Hospital, 7-5-2 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Takehiro OtoshiDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Daisuke HazamaDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Naoko KatsuradaDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Masatsugu YamamotoDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Motoko TachiharaDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Yoshihiro NishimuraDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.
Kazuyuki KobayashiDivision of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-Ku, Kobe, Hyogo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The newly developed portable oxygen concentrator with an auto-demand oxygen delivery system (auto-DODS) automatically switches between 3 sensitivities according to the negative pressure gradient of inhalation and supplies oxygen only during inhalation. The aim of this study was to verify the effectiveness and safety of auto-demand devices compared with a continuous flow oxygen concentrator, during sleep, in a randomized crossover noninferiority trial. We alternatively used an auto-DODS or a continuous-flow oxygen concentrator, all night on separate days for HOT (Home Oxygen Therapy) patients with nocturnal hypoxemic symptoms. The primary endpoints were the mean value of oxygen saturation (SpO

Indexed as

Cross-Over StudiesHypoxiaOxygenOxygen Inhalation TherapyAdultAgedFemaleHumansMaleMiddle AgedOxygen SaturationOxygenAuto-demand deviceChronic respiratory failureHome oxygen therapyStationary device

Identifiers

PMID39227657
PMCPMC11372129

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.