Evidence map›Paper›PMID 39226927›Full record

ArticleJournal of the Royal Society, Interface2024

Adaptive and self-learning Bayesian filtering algorithm to statistically characterize and improve signal-to-noise ratio of heart-rate data in wearable devices.

Luca Cossu, Giacomo Cappon, Andrea Facchinetti

Abstract read
In one paragraph

Article in Journal of the Royal Society, Interface, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Luca CossuDepartment of Information Engineering, University of Padova , Padova, Italy.ORCID 0000-0002-8804-0722
Giacomo CapponDepartment of Information Engineering, University of Padova , Padova, Italy.ORCID 0000-0003-4358-9268
Andrea FacchinettiDepartment of Information Engineering, University of Padova , Padova, Italy.ORCID 0000-0001-8041-2280

Funding

Horizon 2020 Framework Programme
6 · The paper itself

Abstract

The use of wearable sensors to monitor vital signs is increasingly important in assessing individual health. However, their accuracy often falls short of that of dedicated medical devices, limiting their usefulness in a clinical setting. This study introduces a new Bayesian filtering (BF) algorithm that is designed to learn the statistical characteristics of signal and noise, allowing for optimal smoothing. The algorithm is able to adapt to changes in the signal-to-noise ratio (SNR) over time, improving performance through windowed analysis and Bayesian criterion-based smoothing. By evaluating the algorithm on heart-rate (HR) data collected from Garmin Vivoactive 4 smartwatches worn by individuals with amyotrophic lateral sclerosis and multiple sclerosis, it is demonstrated that BF provides superior SNR tracking and smoothing compared with non-adaptive methods. The results show that BF accurately captures SNR variability, reducing the root mean square error from 2.84 bpm to 1.21 bpm and the mean absolute relative error from 3.46% to 1.36%. These findings highlight the potential of BF as a preprocessing tool to enhance signal quality from wearable sensors, particularly in HR data, thereby expanding their applications in clinical and research settings.

Indexed as

AlgorithmsBayes TheoremHeart RateSignal-To-Noise RatioWearable Electronic DevicesFemaleHumansMaleSignal Processing, Computer-Assistedautoregressive modelBayesian filteringheart-rate datanoise reductionsignal processing

Identifiers

PMID39226927
PMCPMC11463221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.