Evidence map›Paper›PMID 39226539›Full record

ArticleChemistryOpen2024

Facile Determination of Aluminum Content in Industrial Brine by Investigating the Effects of Buffer Systems.

Benjámin Csorba, László Farkas, Marcell Csécsi, László T Mika, Iván L Gresits

Abstract read
In one paragraph

Article in ChemistryOpen, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Benjámin CsorbaDepartment of Chemical and Environmental Process Engineering, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., H-1111, Budapest, Hungary.ORCID https://orcid.org/0000-0002-3890-4369
László FarkasProcess Technology Support, BorsodChem Ltd., Bolyai tér 1., H-3700, Kazincbarcika, Hungary.ORCID https://orcid.org/0000-0003-4328-486X
Marcell CsécsiProcess Technology Support, BorsodChem Ltd., Bolyai tér 1., H-3700, Kazincbarcika, Hungary.ORCID https://orcid.org/0009-0009-8150-8650
László T MikaDepartment of Chemical and Environmental Process Engineering, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., H-1111, Budapest, Hungary.ORCID https://orcid.org/0000-0002-8520-0065
Iván L GresitsDepartment of Chemical and Environmental Process Engineering, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., H-1111, Budapest, Hungary.ORCID https://orcid.org/0000-0002-2965-8354

Funding

Ministry of Culture and Innovation of Hungary from the National Research, Development and Innovation FundWanhua-BorsodChem Ltd, Kazincbarcika, Hungary C1340882
6 · The paper itself

Abstract

The aluminum content of concentrated (27 wt%) sodium chloride solutions could be crucial for large-scale chlor-alkali-based industries applying membrane cell electrolysis. Thus, a facile method which enables a fast and reliable protocol to determine the Al content of these solutions on ppb scale in industrial environments is fundamentally important. It was demonstrated that the increased sensitivity of colorful Al-ECR (eriochrome cyanine R) complex by the use of a cationic surfactant and specific biological buffers could effectively indicate the Al content in an extended pH interval of a concentrated saline medium under industrial conditions. The dependence of the analytical protocol on pH, temperature, time, wavelength, and the salinity of the medium was investigated. It was shown that the absorbance-based measurements of the solution should be performed at least 2-4 h after its preparation. By applying the selected two Good's buffers (HEPES: 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, MOPS: 3-(N-morpholino)-propanesulfonic acid) and Tris (tris(hydroxymethyl)aminomethane), 32.8-38.1 % increase in the sensitivity was achieved for saturated NaCl solutions. Moreover, the limits of detection and quantification (LOD, LOQ) were also lowered by 19.0-29.8 %, and the salinity dependence of the calibration was also reduced.

Indexed as

AluminumEriochrome cyanine RGood's buffersIndustrial analyticsUV/Vis spectroscopy

Identifiers

PMID39226539
PMCPMC11625942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.