In one paragraph

Article in Clinical neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. CREST-2 findings are unchanged using an aggregated control group for the CAS and CEA trial.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mousa ZidanDepartment of Neuroradiology, Bonn University Hospital, Venusberg-Campus1, Gebäude 81, 53127, Bonn, Germany. mousa.zidan@ukbonn.de.ORCID http://orcid.org/0000-0002-5236-3992
Yves Leonard VossRadprax MVZ Nordrhein GmbH, Department of Interventional Neuroradiology, St. Lukas-Klinik, Solingen, Germany.
Marcel WolfDepartment of Neuroradiology, Mainz University Hospital, Mainz, Germany.
Fee KeilDepartment of Neuroradiology, Frankfurt University Hospital, Frankfurt, Germany.
Carolin BrockmannDepartment of Neuroradiology, Mainz University Hospital, Mainz, Germany.
Christian GronemannDepartment of Neuroradiology, Bonn University Hospital, Venusberg-Campus1, Gebäude 81, 53127, Bonn, Germany.
Nils Christian LehnenDepartment of Neuroradiology, Bonn University Hospital, Venusberg-Campus1, Gebäude 81, 53127, Bonn, Germany.
Daniel PaechDepartment of Neuroradiology, Bonn University Hospital, Venusberg-Campus1, Gebäude 81, 53127, Bonn, Germany.
Hannes NordmeyerRadprax MVZ Nordrhein GmbH, Department of Interventional Neuroradiology, St. Lukas-Klinik, Solingen, Germany.
Franziska DornDepartment of Neuroradiology, Bonn University Hospital, Venusberg-Campus1, Gebäude 81, 53127, Bonn, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDual-layer stents have fallen into disrepute after several studies reported high rates of in-stent occlusions in acute stroke treatments. The CGuard stent is a new-generation hybrid dual-layer stent that has been designed to provide less thrombogenicity and to prevent peri- and postinterventional emboli. The aim of the study is to evaluate the safety and efficacy of the CGuard stent for the acute treatment of occlusion or high-grade stenosis of the extracranial internal carotid artery (ICA) in patients with acute ischemic stroke (AIS) with and without concomitant intracranial large vessel occlusion (LVO).

methodsAll patients who underwent emergent carotid artery stenting (CAS) with the CGuard stent were identified and analyzed from the stroke registries from four tertiary German stroke centers. Clinical, procedural, and imaging data were evaluated. Stent patency within 72 h, intracranial hemorrhage, and modified Rankin score (mRS) at discharge were the safety and efficacy end points.

resultsOverall, ninety-six patients were included (mean age 70.2 ± 11.8, 66 males (68.8%), median NIHSS score at admission 11 (7-17), IV lysis: n = 44 (45.8%)). Stent placement was successful in all patients. Eighty-three (86.4%) patients had tandem occlusions. In-stent occlusion occurred in 5 patients (5.2%) and 3 patients developed early in-stent stenosis (3.1%). Median mRS at discharge was 2 (1-4).

conclusionIn this multicenter study, the use of the dual-layer CGuard stent for emergent CAS, particularly in tandem occlusions, was safe and resulted in low rates of in-stent occlusions.

Indexed as

Carotid StenosisIschemic StrokeStentsAgedAged, 80 and overCarotid Artery, InternalFemaleGermanyHumansMaleMiddle AgedRegistriesRetrospective StudiesTreatment OutcomeCarotid artery stentingDual-layer stentIn-stent occlusionTandem occlusionThrombectomy

Identifiers

PMID39225802
PMCPMC11832600

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.