ArticleClinical neuroradiology2025
The Dual-layer CGuard Stent Is Safe and Effective in Emergent Carotid Artery Stenting and in Tandem Occlusions: a Multi-centric Study.
Article in Clinical neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- CREST-2 findings are unchanged using an aggregated control group for the CAS and CEA trial.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDual-layer stents have fallen into disrepute after several studies reported high rates of in-stent occlusions in acute stroke treatments. The CGuard stent is a new-generation hybrid dual-layer stent that has been designed to provide less thrombogenicity and to prevent peri- and postinterventional emboli. The aim of the study is to evaluate the safety and efficacy of the CGuard stent for the acute treatment of occlusion or high-grade stenosis of the extracranial internal carotid artery (ICA) in patients with acute ischemic stroke (AIS) with and without concomitant intracranial large vessel occlusion (LVO).
methodsAll patients who underwent emergent carotid artery stenting (CAS) with the CGuard stent were identified and analyzed from the stroke registries from four tertiary German stroke centers. Clinical, procedural, and imaging data were evaluated. Stent patency within 72 h, intracranial hemorrhage, and modified Rankin score (mRS) at discharge were the safety and efficacy end points.
resultsOverall, ninety-six patients were included (mean age 70.2 ± 11.8, 66 males (68.8%), median NIHSS score at admission 11 (7-17), IV lysis: n = 44 (45.8%)). Stent placement was successful in all patients. Eighty-three (86.4%) patients had tandem occlusions. In-stent occlusion occurred in 5 patients (5.2%) and 3 patients developed early in-stent stenosis (3.1%). Median mRS at discharge was 2 (1-4).
conclusionIn this multicenter study, the use of the dual-layer CGuard stent for emergent CAS, particularly in tandem occlusions, was safe and resulted in low rates of in-stent occlusions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.