Evidence map›Paper›PMID 39224750›Full record

ArticleJournal of experimental orthopaedics2024

Robotic Assisted TKA achieves adjusted mechanical alignment targets more consistently compared to manual TKA without improving outcomes.

Ashok Rajgopal, Sriram Surendra Sundararajan, Kalpana Aggarwal, Sumit Kumar, Gargi Singh

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Observational
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ashok RajgopalInstitute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India.ORCID https://orcid.org/0000-0001-6106-6140
Sriram Surendra SundararajanInstitute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India.
Kalpana AggarwalInstitute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India.
Sumit KumarInstitute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India.
Gargi SinghInstitute of Education and Research Medanta-The Medicity Hospital Gurugram India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Robotic total knee arthroplasty (rTKA), with its purported advantages of more accurate alignment, greater functional outcomes and patient satisfaction, is gaining popularity in patients undergoing TKA. The purpose of our study was to compare these parameters along with gait pattern and kneeling ability in a cohort of patients who underwent simultaneous TKA with manual instrumentation (mTKA) and rTKA in contralateral knees at a 1-year follow-up. Methods: This was a retrospective review of 135 consecutive patients who underwent simultaneous bilateral TKA using robotic assistance on one side and manual instrumentation on the contralateral side between January 2022 and June 2022. The target alignment in both cohorts was adjusted mechanical. Patients were followed up at 3, 6 and 12 months to assess and compare alignment, range of motion (ROM) and patient-reported outcome measures (PROM) data. Gait parameters and kneeling ability were assessed at 1-year follow-up. Results: While adjusted mechanical alignment was achieved in all rTKA patients, we recorded five outliers (≥3° with relation to 180° HKA axis) in the mTKA cohort (three varus and two valgus). There were no significant differences between both cohorts with regards to ROM, PROM scores, gait analysis parameters and kneeling ability at 1-year follow-up. Conclusion: rTKA helps in achieving the adjusted mechanical alignment more consistently than mTKA. This, however, does not contribute to better functional outcomes and patient satisfaction at 1-year follow-up. Level of Evidence: Level III.

Indexed as

conventional total knee arthroplastygait analysispatient reported outcome measuresrange of motionrobotic total knee arthroplasty

Identifiers

PMID39224750
PMCPMC11366966

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.