Evidence map›Paper›PMID 39223520›Full record

ArticleBMC musculoskeletal disorders2024

Biomechanical difference analysis of new and classic intramedullary nail devices in the treatment of basal femoral neck fractures: finite element analysis.

Zhongjian Tang, Zhexi Zhu, Yongxiang Lv, Yafei Lu, Shaolong Huang, Chengqiang Zhou, Yazhong Zhang, Bin Wang

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhongjian Tang *Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Zhexi Zhu *Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Yongxiang LvDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Yafei LuDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Shaolong HuangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Chengqiang ZhouThe First Affiliated Hospital of Chongqing Medical University, Chongqing, 400000, China.
Yazhong ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China.
Bin WangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, 221000, China. wangbin_injury1989@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThere is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF.

methodsBased on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing.

resultsUnder a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS.

conclusionThe PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.

Indexed as

Bone NailsFemoral Neck FracturesFinite Element AnalysisFracture Fixation, IntramedullaryBiomechanical PhenomenaHumansStress, MechanicalWeight-BearingBasal femoral neck fracturesFinite element analysisIntramedullary nail devicesNew intramedullary systemsProximal femoral bionic nails

Identifiers

PMID39223520
PMCPMC11370041

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.