Evidence map›Paper›PMID 39221690›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2025

Evaluation of guided reporting: quality and reading time of automatically generated radiology report in breast magnetic resonance imaging using a dedicated software solution.

Martin H Maurer, Daniel Lorenz, Maximilian Clemens Otterbach, Igor Toker, Alexander Huppertz

Abstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Martin H MaurerUniversitätsinstitut für Diagnostische und Interventionelle Radiologie, Klinikum Oldenburg AöR, Department of Diagnostic and Interventional Radiology, Oldenburg, Germany.ORCID 0000-0003-0153-3987
Daniel LorenzNeo Q Quality in Imaging GmbH, Berlin, Germany.ORCID 0009-0003-0875-4683
Maximilian Clemens OtterbachUniversitätsinstitut für Diagnostische und Interventionelle Radiologie, Klinikum Oldenburg AöR, Department of Diagnostic and Interventional Radiology, Oldenburg, Germany.ORCID 0009-0008-5900-6972
Igor TokerNeo Q Quality in Imaging GmbH, Berlin, Germany.ORCID 0000-0002-8550-1634
Alexander HuppertzNeo Q Quality in Imaging GmbH, Berlin, Germany.ORCID 0009-0004-4862-2455

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeUnstructured, free-text dictation (FT), the current standard in breast magnetic resonance imaging (MRI) reporting, is considered time-consuming and prone to error. The purpose of this study is to assess the usability and performance of a novel, software-based guided reporting (GR) strategy in breast MRI.

methodsEighty examinations previously evaluated for a clinical indication (e.g., mass and focus/non-mass enhancement) with FT were reevaluated by three specialized radiologists using GR. Each radiologist had a different number of cases (R1, n = 24; R2, n = 20; R3, n = 36). Usability was assessed by subjective feedback, and quality was assessed by comparing the completeness of automatically generated GR reports with that of their FT counterparts. Errors in GR were categorized and analyzed for debugging with a final software version. Combined reading and reporting times and learning curves were analyzed.

resultsUsability was rated high by all readers. No non-sense, omission/commission, or translational errors were detected with the GR method. Spelling and grammar errors were observed in 3/80 patient reports (3.8%) with GR (exclusively in the discussion section) and in 36/80 patient reports (45%) with FT. Between FT and GR, 41 patient reports revealed no content differences, 33 revealed minor differences, and 6 revealed major differences that resulted in changes in treatment. The errors in all patient reports with major content differences were categorized as content omission errors caused by improper software operation (n = 2) or by missing content in software v. 0.8 displayable with v. 1.7 (n = 4). The mean combined reading and reporting time was 576 s (standard deviation: 327 s; min: 155 s; max: 1,517 s). The mean times for each reader were 485, 557, and 754 s, and the respective learning curves evaluated by regression models revealed statistically significant slopes (

conclusionGR allows for complete reporting with minimized error rates and reduced combined reading and reporting times. The streamlining of the process (evidenced by lower reading times) for the readers in this study proves that GR can be learned quickly. Reducing reporting errors leads to fewer therapeutic faults and lawsuits against radiologists. It is known that delays in radiology reporting hinder early treatment and lead to poorer patient outcomes. CLINICAL SIGNIFICANCE: While the number of scans and images per examination is continuously rising, staff shortages create a bottleneck in radiology departments. The IT-based GR method can be a major boon, improving radiologist efficiency, report quality, and the quality of simultaneously generated data.

Indexed as

Breast NeoplasmsMagnetic Resonance ImagingSoftwareAdultAgedBreastFemaleHumansMiddle AgedRadiology Information SystemsTime FactorsBreast magnetic resonance imagingclinical informaticshuman interactionsqualityradiology reportradiology workflowsoftware-based reportingstructured reportingworkflows

Identifiers

PMID39221690
PMCPMC11701694

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.