ArticlePhotoacoustics2024
Laser ultrasonic detection for defects of LAM components based on variable time window intensity mapping with adaptive 2σ thresholds.
Article in Photoacoustics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Metallurgical defects in metal laser additive manufacturing (LAM) are inevitable due to complex non-equilibrium thermodynamics. A laser ultrasonic system was designed for detecting surface/near-surface defects in the layer-by-layer LAM process. An approach was proposed for ultrasonic imaging of defects based on variable time window intensity mapping with adaptive 2σ threshold denoising. The Gaussian mixture model hypothesis and expectation-maximization algorithm can automatically differentiate between components dominated by defects and background noises, thereby providing an adaptive threshold that accommodates detection environments and surface roughness levels. Results show that the ultrasonic wave reflection at defect boundaries diminishes far-field ultrasonic intensity upon pulsed laser irradiation on surface defects, enabling defect size and location characterization. This method is applicable to LAM samples with a significant surface roughness of up to 37.5 μm. It can detect superficial and near-surface defects down to 0.5 mm in diameter and depth, making it significant for online defect detection in additive manufacturing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.