Evidence map›Paper›PMID 39221417›Full record

ArticleThe journal of advanced prosthodontics2024

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis.

Peter Gehrke, Maria Julia Pietruska, Johannes Ladewig, Carsten Fischer, Robert Sader, Paul Weigl

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Peter GehrkeDepartment of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0002-0412-5615
Maria Julia PietruskaPrivate Practice for Oral Surgery and Implant Dentistry, Ludwigshafen, Germany.ORCID https://orcid.org/0000-0003-3004-6643
Johannes LadewigPrivate Practice for Implant Dentistry, Berlin, Germany.ORCID https://orcid.org/0009-0006-9452-2572
Carsten FischerDental Laboratory, Sirius Ceramics, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0003-0753-311X
Robert SaderDepartment for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Medical Center, University Hospital, Goethe University Frankfurt, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0002-0265-0301
Paul WeiglDepartment of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0001-7434-7988

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND

methodsFor single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔE

resultsThe color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of all-ceramic crowns. There was a significant difference (

conclusionVarious cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

Indexed as

CementCeramic copingColorSoft tissueTi-base abutment

Identifiers

PMID39221417
PMCPMC11361822

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.