Evidence map›Paper›PMID 39220226›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2024

Discrete Wavelet Transformation for the Sensitive Detection of Ultrashort Radiation Pulse with Radiation-induced Acoustics.

Rick van Bergen, Leshan Sun, Prabodh Kumar Pandey, Siqi Wang, Kristina Bjegovic, Gilberto Gonzalez, Yong Chen, Richard Lopata, Liangzhong Xiang

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rick van BergenPULS/e lab Eindhoven, Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands.
Leshan SunDepartment of Biomedical Engineering, University of California Irvine, Irvine, CA 92617.
Prabodh Kumar PandeyDepartment of Radiological Sciences, University of California Irvine, Irvine, CA 92617.
Siqi WangDepartment of Biomedical Engineering, University of California Irvine, Irvine, CA 92617.
Kristina BjegovicDepartment of Biomedical Engineering, University of California Irvine, Irvine, CA 92617.
Gilberto GonzalezDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104.
Yong ChenDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104.
Richard LopataPULS/e lab Eindhoven, Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands.
Liangzhong XiangDepartment of Biomedical Engineering, University of California Irvine, Irvine, CA 92617.; Department of Radiological Sciences, University of California Irvine, Irvine, CA 92617.; Beckman Laser Institute Medical Clinic, University of California Irvine, Irvine, CA 92612.

Funding

Univ.of Calif., Irvine Cancer Center Support GrantP30CA062203 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI Christine Hui · 1994 to 2026
$57.9M
Academic-Industry Partnership for the Translation of a 4D in vivo Dosimetry Approach for Radiation TherapyR37CA240806 · NCI · UNIVERSITY OF OKLAHOMA · PI CHEN, YONG, IVANOV, VASSILI · 2019 to 2025
$2.9M
NCI NIH HHS P30 CA062203NCI NIH HHS R37 CA240806
6 · The paper itself

Abstract

Radiation-induced acoustics (RIA) shows promise in advancing radiological imaging and radiotherapy dosimetry methods. However, RIA signals often require extensive averaging to achieve reasonable signal-to-noise ratios, which increases patient radiation exposure and limits real-time applications. Therefore, this paper proposes a discrete wavelet transform (DWT) based filtering approach to denoise the RIA signals and avoid extensive averaging. The algorithm was benchmarked against low-pass filters and tested on various types of RIA sources, including low-energy X-rays, high-energy X-rays, and protons. The proposed method significantly reduced the required averages (1000 times less averaging for low-energy X-ray RIA, 32 times less averaging for high-energy X-ray RIA, and 4 times less averaging for proton RIA) and demonstrated robustness in filtering signals from different sources of radiation. The coif5 wavelet in conjunction with the sqtwolog threshold selection algorithm yielded the best results. The proposed DWT filtering method enables high-quality, automated, and robust filtering of RIA signals, with a performance similar to low-pass filtering, aiding in the clinical translation of radiation-based acoustic imaging for radiology and radiation oncology.

Indexed as

Discrete Wavelet FilteringRadiation Induced AcousticsRadiation monitoring

Identifiers

PMID39220226
PMCPMC11364354

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.