Evidence map›Paper›PMID 39220115›Full record

ArticlePhysics and imaging in radiation oncology2024

The impact of plan complexity on calculation and measurement-based pre-treatment verifications for sliding-window intensity-modulated radiotherapy.

Shi Li, Huanli Luo, Xia Tan, Tao Qiu, Xin Yang, Bin Feng, Liyuan Chen, Ying Wang, Fu Jin

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. The smoothing factor in breast intensity-modulated radiotherapy: dosimetric impact and a predictive model of plan acceptability.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Shi LiDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Huanli LuoDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Xia TanDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Tao QiuDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Xin YangDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Bin FengDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Liyuan ChenDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Ying WangDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.
Fu JinDepartments of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: In sliding-window intensity-modulated radiotherapy, increased plan modulation often leads to increased plan complexities and dose uncertainties. Dose calculation and/or measurement checks are usually adopted for pre-treatment verification. This study aims to evaluate the relationship among plan complexities, calculated doses and measured doses. Materials and methods: A total of 53 plan complexity metrics (PCMs) were selected, emphasizing small field characteristics and leaf speed/acceleration. Doses were retrieved from two beam-matched treatment devices. The intended dose was computed employing the Anisotropic Analytical Algorithm and validated through Monte Carlo (MC) and Collapsed Cone Convolution (CCC) algorithms. To measure the delivered dose, 3D diode arrays of various geometries, encompassing helical, cross, and oblique cross shapes, were utilized. Their interrelation was assessed via Spearman correlation analysis and principal component linear regression (PCR). Results: The correlation coefficients between calculation-based (CQA) and measurement-based verification quality assurance (MQA) were below 0.53. Most PCMs showed higher correlation Conclusions: CQA and MQA demonstrated a weak correlation. Compared to MQA, CQA exhibited a stronger correlation with PCMs. Certain PCMs related to MLC movement effectively indicated variations in both quality assurances.

Indexed as

3D diode arraysAlgorithmDosimetric accuracyPlan complexity metricPretreatment verifications

Identifiers

PMID39220115
PMCPMC11364123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.