Evidence map›Paper›PMID 39218609›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2024

[Research on dynamic blood oxygen saturation measurement based on motion noise reconstruction combined with convex combination least mean square adaptive filter].

Linjia Zhang, Xiaomin Yu, Jian Lin, Chengen Chou, Zhengxian Wang

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Linjia ZhangKey Laboratory of Biomedical Effect of Physical Field and Instrument, School of Electrical and Electronic Engineering, Chengdu University of Information Technology, Chengdu 610225, P. R. China.
Xiaomin YuKey Laboratory of Biomedical Effect of Physical Field and Instrument, School of Electrical and Electronic Engineering, Chengdu University of Information Technology, Chengdu 610225, P. R. China.
Jian LinSichuan Acad Medicine Science & Sichuan Province Peoples Hospital, Chengdu 610072, P. R. China.
Chengen ChouSichuan Acad Medicine Science & Sichuan Province Peoples Hospital, Chengdu 610072, P. R. China.
Zhengxian WangKey Laboratory of Biomedical Effect of Physical Field and Instrument, School of Electrical and Electronic Engineering, Chengdu University of Information Technology, Chengdu 610225, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The performance of a pulse oximeter based on photoelectric detection is greatly affected by motion noise (MA) in the photoplethysmographic (PPG) signal. This paper presents an algorithm for detecting motion oxygen saturation, which reconstructs a motion noise reference signal using ensemble of complete adaptive noise and empirical mode decomposition combined with multi-scale permutation entropy, and eliminates MA in the PPG signal using a convex combination least mean square adaptive filters to calculate dynamic oxygen saturation. The test results show that, under simulated walking and jogging conditions, the mean absolute error (MAE) of oxygen saturation estimated by the proposed algorithm and the reference oxygen saturation are 0.05 and 0.07, respectively, with means absolute percentage error (MAPE) of 0.05% and 0.07%, respectively. The overall Pearson correlation coefficient reaches 0.971 2. The proposed scheme effectively reduces motion artifacts in the corrupted PPG signal and is expected to be applied in portable photoelectric pulse oximeters to improve the accuracy of dynamic oxygen saturation measurement.

Indexed as

AlgorithmsArtifactsOximetryOxygen SaturationPhotoplethysmographySignal Processing, Computer-AssistedHumansLeast-Squares AnalysisMotionOxygenOxygenBlood oxygen saturationMotion noiseNoise reconstructionPhotoplethysmographicSignal decomposition

Identifiers

PMID39218609
PMCPMC11366476

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.