Evidence map›Paper›PMID 39218603›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2024

[Design of nonlinear locking mechanism for shape memory alloy archwire of miniature orthodontic device].

Qingyuan Dai, Li Ji, Jiahao Hua, Zhenyu Liang, Jianwen Yu, Taicong Chen

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Qingyuan DaiSchool of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, P. R. China.
Li JiThe First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, P. R. China.
Jiahao HuaSchool of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, P. R. China.
Zhenyu LiangSchool of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, P. R. China.
Jianwen YuGuangzhou OO Medical Scientific Limited, Guangzhou 510080, P. R. China.
Taicong ChenSchool of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The locking mechanism between bracket and shape memory alloy (SMA) archwire in the newly developed domestic orthodontic device is the key to controlling the precise alignment of the teeth. To meet the demand of locking force in clinical treatment, the tightening torque angle of the locking bolt and the required torque magnitude need to be precisely designed. For this purpose, a design study of the locking mechanism is carried out to analyze the correspondence between the tightening torque angle and the locking force and to determine the effective torque value, which involves complex coupling of contact, material and geometric nonlinear characteristics. Firstly, a simulation analysis based on parametric orthogonal experimental design is carried out to determine the SMA hyperelastic material parameters for the experimental data of SMA archwire with three-point bending. Secondly, a two-stage fine finite-element simulation model for bolt tightening and archwire pulling is established, and the nonlinear analysis is converged through the optimization of key contact parameters. Finally, multiple sets of calibration experiments are carried out for three tightening torsion angles. The comparison results between the design analysis and the calibration experiments show that the deviation between the design analysis and the calibration mean value of the locking force in each case is within 10%, and the design analysis method is valid and reliable. The final tightening torque angle for clinical application is determined to be 10° and the rated torque is 2.8 N∙mm. The key data obtained can be used in the design of clinical protocols and subsequent mechanical optimization of novel orthodontic devices, and the research methodology can provide a valuable reference for force analysis of medical devices containing SMA materials.

Indexed as

Finite Element AnalysisOrthodontic WiresTorqueComputer SimulationDental Stress AnalysisHumansMaterials TestingOrthodontic Appliance DesignOrthodontic BracketsShape Memory AlloysStress, MechanicalShape Memory AlloysLocking mechanicsOrthodontic deviceOrthogonal design of experimentShape memory alloy

Identifiers

PMID39218603
PMCPMC11366461

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.