ArticleBMC musculoskeletal disorders2024
Nonanatomical reduction of femoral neck fractures in young patients with different Pauwels classifications: a retrospective study and finite element analysis.
Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Article
- 3D-printed navigation-guided FNS-CCS fixation reduces complications in young adults with comminuted femoral neck fractures: a retrospective cohort study.BMC musculoskeletal disorders · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
backgroundPrevious studies have reported that positive buttress is as effective as anatomical reduction in treating young femoral neck fractures, but whether this effect is related to the Pauwels classification remains unclear. The purpose of this study was to retrospectively analyze the clinical prognosis of positive buttress in young femoral neck fractures with different Pauwels classifications, as well as to assess its biomechanical properties.
methodsA total of 170 young patients with femoral neck fractures who were treated with three cannulated screws were included in this study. Patients were divided into three groups based on their preoperative Pauwels classification. Each group was divided into three subgroups based on the reduction quality: positive buttress, negative buttress and anatomical reduction. The femoral neck shortening, the incidence of necrosis of the femoral head (AVN) and the Harris hip scores at the last follow-up were compared across the three reduction quality within each Pauwels classification. Subsequently, a volunteer was recruited, CT data of the hip was obtained, and finite element models representing different reduction quality under varying Pauwels classifications were established. The biomechanical properties of each model were then evaluated following the application of strains.
resultsIn Pauwels type I, there were no significant differences in postoperative femoral neck shortening, incidence of AVN, or Harris score among the three types of reduction quality (P > 0.05). However, positive buttress provided superior biomechanical stability compared to negative buttress and anatomical reduction. In Pauwels type II, the incidence of AVN was similar between the positive buttress and the anatomical reduction groups, and both were significantly lower than that in the negative buttress (P < 0.05). The Harris score of the positive buttress was higher than that of the negative buttress, and there was no significant difference in the occurrence of femoral neck shortening between the three groups (P > 0.05). Finite element analysis showed that the biomechanical stability of positive buttress was equivalent to anatomical reduction, and both were better than negative buttress. In Pauwels type III, the incidence of AVN in the anatomical reduction group was lower than that in both the positive buttress and negative buttress (P < 0.05). There was no significant difference in the occurrence of AVN or femoral neck shortening between positive buttress and negative buttress (P > 0.05). There was also no difference in postoperative Harris scores between the three reduction qualities (P > 0.05). Both positive buttress and negative buttress exhibited identical biomechanical qualities and were inferior to anatomical reduction.
conclusionsThe biomechanical and clinical dominance of positive buttress correlates with Pauwels type. Specifically, Positive buttress is biomechanically stable in Pauwels types I and II. In Pauwels type III, positive buttress is not advantageous. As the Pauwels angle increases, the biomechanical benefit of the positive buttress is lost. Therefore, regardless of the Pauwels classification, negative buttress should be avoided after reduction of femoral neck fractures in young patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.