Evidence map›Paper›PMID 39217319›Full record

ArticleBMC musculoskeletal disorders2024

Bispherical metal augment improved biomechanical stability in severe acetabular deficiency reconstruction: a comparative finite element analysis.

Guoyuan Li, Xiaoqi Zhang, Min Chen, Zhengliang Luo, Xiaofeng Ji, Chunang Pan, Hui Li, Xi-Fu Shang

Erratum issuedAbstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Guoyuan LiDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China.
Xiaoqi ZhangDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China.
Min ChenDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China.
Zhengliang LuoDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China.
Xiaofeng JiDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China.
Chunang PanBeijing Engineering and Technology Research Center for Medical Endoplant, Beijing, 100000, People's Republic of China.
Hui LiBeijing Engineering and Technology Research Center for Medical Endoplant, Beijing, 100000, People's Republic of China.
Xi-Fu ShangDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, 17 Lujiang Road, Hefei, 230000, People's Republic of China. shangxifu@163.com.

Funding

the Joint Fund for Medical Artificial Intelligence MAI2023Q027the National Natural Science Foundation of China 81902201the Natural Science Foundation of Anhui Province 2308085MH251
6 · The paper itself

Abstract

backgroundThis study used finite element analysis (FEA) to compare the biomechanical stability of bispherical metal augment (BA) and wedge-shaped trabecular-metal augment (TA) in different acetabular defect reconstruction models, thereby explaining the application value of this novel bispherical augment in complex hip revision.

methodsThree different acetabular defect pelvis models originating from three representative patients with different types of severe acetabular defects (Paprosky IIC, IIIA, and IIIB) were constructed and reconstruction with BA and TA technique was simulated. Based on the FEA models, the displacement of reconstruction implants, relative displacement of bone implants, and hemi-pelvic von Mises stress were investigated under static loads.

resultsBA acquired smaller reconstruction system displacement, less relative displacement of bone implants, and lower pelvic von Mises stress than TA in all Paprosky IIC, IIIA, and IIIB defect reconstructions.

conclusionThe FEA results show that BA could acquire favourable biomechanical stability in severe acetabular defect reconstruction. This technique is a reliable method in complex hip revision.

Indexed as

AcetabulumArthroplasty, Replacement, HipFinite Element AnalysisHip ProsthesisBiomechanical PhenomenaFemaleHumansMalePlastic Surgery ProceduresProsthesis DesignStress, MechanicalAcetabular defectAugmentsFinite element analysisRevision total hip arthroplasty

Identifiers

PMID39217319
PMCPMC11365125

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.