Evidence map›Paper›PMID 39216122›Full record

ArticleClinics (Sao Paulo, Brazil)2024

Clinical application of pulse-gated non-enhanced rapid magnetic resonance imaging in the definitive diagnosis of aortic dissection.

QinWen Yan, Gang Hu, Qin Wang, Lei Wu, Jun Zhang, Lan He, CiLai Jiao, Si Ma, MinChao Xiong

Abstract read
In one paragraph

Article in Clinics (Sao Paulo, Brazil), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

QinWen YanDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Gang HuDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Qin WangDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Lei WuDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Jun ZhangDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Lan HeDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
CiLai JiaoDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
Si MaDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China.
MinChao XiongDepartment of Medical Imaging (Radiology), Ezhou Central Hospital Affiliated to Hubei University of Science and Technology, Ezhou City, Hubei Province, PR China. Electronic address: xiongminchaodr@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAortic Dissection (AD) is one of the most fatal acute diseases in cardiovascular diseases, with rapid onset and progression and a high fatality rate. This study aims to investigate the clinical values of non-enhancement peripheral pulse-gating rapid magnetic resonance imaging in deterministic diagnosis of AD.

methodsAorta magnetic resonance imaging was performed in 21 healthy volunteers at a 1.5t MR scanner sequences including cardiac-gated and peripheral pulse-gated True-FISP and HASTE were carried out separately. Acquisition Time (TA), Signal to Noise Ratio (SNR), Contrast Noise Ratio (CNR), and entirety of vessel wall blood flow artifacts were measured and compared. A total of 56 AD cases were displayed by non-enhancement peripheral pulse-gating fast MR imaging, and the results were compared with pathological findings or CTA of the aorta. The dissection rupture, tear film, true and false lumen, thrombosis, hydropericardium, and the main branches of AD were evaluated respectively.

resultsThere were no significant differences in SNR, CNR, entirety of the vessel wall, and blood flow artifact between cardiac-gated and peripheral pulse-gated fast MR imaging. Non-enhancement pulse-gated fast scanning takes less TA time. By the pulse-gated non-enhancement fast MR imaging, the dissection rupture, tear film, true and false cavity, thrombosis, hydropericardium, and the main branches of aortic dissection were shown clearly. Multi-planar and multi-angle scans helped to show the extent of entrapment rupture, whereas partial complex tears or bi-directional tears were slightly less well visualized.

conclusionNon-enhancement peripheral pulse-gated rapid magnetic resonance imaging can be used for deterministic diagnosis of AD.

Indexed as

Aortic DissectionMagnetic Resonance ImagingAdultAgedAortic AneurysmCardiac-Gated Imaging TechniquesFemaleHumansMaleMiddle AgedReference ValuesReproducibility of ResultsSignal-To-Noise RatioYoung AdultAortic dissectionCardiac-gatedHalf-Fourier acquisition single-shot turbo spin echo (HASTE)Magnetic resonance imagingPulse-gatingTrue fast imaging with steady-state precession (True-FISP)

Identifiers

PMID39216122
PMCPMC11402381

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.