Evidence map›Paper›PMID 39214908›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2025

Curvature analysis of CI electrode arrays: a novel approach to categorize perimodiolar positions without anatomical landmarks.

Alexander Mewes, Jan Dambon, Goetz Brademann, Matthias Hey

Abstract read
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexander MewesChristian-Albrecht University of Kiel, Kiel, Germany. stu226070@mail.uni-kiel.de.ORCID http://orcid.org/0009-0004-0173-1216
Jan DambonDepartment of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany.
Goetz BrademannDepartment of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany.
Matthias HeyDepartment of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany.ORCID http://orcid.org/0000-0002-7150-0833

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePerimodiolar electrode arrays may be positioned regular, over-inserted or under-inserted into the cochlea depending on the cochlear size and shape. The study aimed to examine whether there are differences between these groups in the local curvature along the intracochlear array. Individual curvature variables were developed to categorize the groups and the relationship between the curvature and the angular insertion depth at the electrode tip was analyzed.

methodsThe curvature along the intracochlear array was measured in the CBCT image of 85 perimodiolar electrodes of a single type. The mean curvature and the ratio of the mean curvature at contacts E14-16 to the mean curvature at E7-8 (bowing ratio) were calculated across the array, and its true positive rate (TPR) and false positive rate (FPR) were calculated to establish optimal threshold values to categorize the groups.

results68.2% of the cases were categorized as regular positioned, 22.4% had an over-insertion and 9.4% had an under-insertion. The mean curvature was significantly weaker with under-insertion (< 342°) than with normal insertion depth (≥ 342°). With an over-insertion, the bowing ratio was < 1 and otherwise > 1. Both the mean curvature and bowing ratio were found to have an optimal threshold value with high TPR (= 1.00) and low FPR (≤ 0.06) for categorizing under-insertion and over-insertion, respectively.

conclusionCurvature analysis is a useful tool to assess if a perimodiolar electrode array has been inserted deep enough into the cochlea. Independent of critical anatomical landmarks, over-inserted arrays and under-inserted arrays could be well categorized by using individual curvature variables. The results need to be validated using additional data sets.

Indexed as

CochleaCochlear ImplantationCochlear ImplantsElectrodes, ImplantedAdultAgedAnatomic LandmarksCone-Beam Computed TomographyFemaleHumansMaleMiddle AgedaDOIAngular depth of insertionCochlear implantCurvatureOver-insertionUnder-insertion

Identifiers

PMID39214908
PMCPMC11735585

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.