Evidence map›Paper›PMID 39213262›Full record

ArticlePLOS digital health2024

Comparison of professional and everyday wearable technology at different body positions in terms of recording gait perturbations.

Lea Feld, Lena Schell-Majoor, Sandra Hellmers, Jessica Koschate, Andreas Hein, Tania Zieschang, Birger Kollmeier

Abstract read
In one paragraph

Article in PLOS digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
  4. Automatic Detection of Gait Perturbations With Everyday Wearable Technology.IEEE open journal of engineering in medicine and biology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lea FeldDepartment of Medical Physics and Acoustics, Medical Physics and Cluster of Excellence Hearing4all, Carl von Ossietzky University, Oldenburg, Germany.ORCID https://orcid.org/0009-0003-1174-4478
Lena Schell-MajoorDepartment of Medical Physics and Acoustics, Medical Physics and Cluster of Excellence Hearing4all, Carl von Ossietzky University, Oldenburg, Germany.
Sandra HellmersDepartment for Health Services Research, Assistance Systems and Medical Device Technology, Carl von Ossietzky University, Oldenburg, Germany.ORCID https://orcid.org/0000-0002-1686-6752
Jessica KoschateDepartment for Health Services Research, Geriatric Medicine, Carl von Ossietzky University, Oldenburg, Germany.
Andreas HeinDepartment for Health Services Research, Assistance Systems and Medical Device Technology, Carl von Ossietzky University, Oldenburg, Germany.
Tania ZieschangDepartment for Health Services Research, Geriatric Medicine, Carl von Ossietzky University, Oldenburg, Germany.
Birger KollmeierDepartment of Medical Physics and Acoustics, Medical Physics and Cluster of Excellence Hearing4all, Carl von Ossietzky University, Oldenburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Falls are a significant health problem in older people, so preventing them is essential. Since falls are often a consequence of improper reaction to gait disturbances, such as slips and trips, their detection is gaining attention in research. However there are no studies to date that investigated perturbation detection, using everyday wearable devices like hearing aids or smartphones at different body positions. Sixty-six study participants were perturbed on a split-belt treadmill while recording data with hearing aids, smartphones, and professional inertial measurement units (IMUs) at various positions (left/right ear, jacket pocket, shoulder bag, pants pocket, left/right foot, left/right wrist, lumbar, sternum). The data were visually inspected and median maximum cross-correlations were calculated for whole trials and different perturbation conditions. The results show that the hearing aids and IMUs perform equally in measuring acceleration data (correlation coefficient of 0.93 for the left hearing aid and 0.99 for the right hearing aid), which emphasizes the potential of utilizing sensors in hearing aids for head acceleration measurements. Additionally, the data implicate that measurement with a single hearing aid is sufficient and a second hearing aid provides no added value. Furthermore, the acceleration patterns were similar for the ear position, the jacket pocket position, and the lumbar (correlation coefficient of about 0.8) or sternal position (correlation coefficient of about 0.9). The correlations were found to be more or less independent of the type of perturbation. Data obtained from everyday wearable devices appears to represent the movements of the human body during perturbations similar to that of professional devices. The results suggest that IMUs in hearing aids and smartphones, placed at the trunk, could be well suited for an automatic detection of gait perturbations.

Identifiers

PMID39213262
PMCPMC11364241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked