ArticleThe archives of bone and joint surgery2024
Preoperative Three-Dimensional Planning of Screw Length is not Reliable in Osteotomies of the Humerus and Forearm.
Article in The archives of bone and joint surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Strategies for surgical reconstruction of complex elbow deformities based on patient-specific instruments - a case series and narrative review.Innovative surgical sciences · 2026Article
- Occupational and Non-Occupational Risk Factors for Neck Pain in Dentists: A Systematic Review and Meta-Analysis.The archives of bone and joint surgery · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: Pediatric upper extremity fractures are seen frequently and sometimes lead to malunion. Three-dimensional (3D) surgery planning is an innovative addition to surgical treatment for the correction of post-traumatic arm deformities. The detailed planning in three dimensions allows for optimization of correction and provides planning of the exact osteotomies which include the advised material for correction and fixation. However, no literature is available on the precision of this computerized sizing of implants and screws. This study aimed to investigate the differences between 3D planned and surgically implanted screws in patients with a corrective osteotomy of the arm. Methods: Planned and implanted screw lengths were evaluated in patients who underwent a 3D planned corrective osteotomy of the humerus or forearm using patient-specific 3D printed drill- and sawblade guides. Postoperative information on implanted hardware was compared to the original planned screw lengths mentioned in the 3D planned surgery reports. Results: Of the 159 included screws in 17 patients, 45% differed >1 mm from the planned length (P<0.001). Aberrant screws in the radius and ulna were often longer, while those in the humerus were often shorter. Most aberrant screws were seen in the proximity of the elbow joint. Conclusion: This study showed that 3D-planned screws in corrective osteotomies of the humerus and forearm differ significantly from screw lengths used during surgery. This illustrates that surgeons should be cautious when performing osteotomies with 3D techniques and predefined screw sizes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.