Evidence map›Paper›PMID 39210475›Full record

ArticleJournal of neuroengineering and rehabilitation2024

Soft pneumatic actuators for pushing fingers into extension.

James V McCall, Gregory D Buckner, Derek G Kamper

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

James V McCallJoint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, North Carolina State University, Chapel Hill, NC, 27599, USA.
Gregory D BucknerDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, 27695, USA.
Derek G KamperJoint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, North Carolina State University, Chapel Hill, NC, 27599, USA. dgkamper@ncsu.edu.

Funding

A multimodal intervention to improve manual dexterity in subacute stroke survivorsR21HD105874 · NICHD · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI KAMPER, DEREK · 2021 to 2022
$397k
NICHD NIH HHS R21 HD105874NIH HHS 5R21HD105874-02
6 · The paper itself

Abstract

backgroundCompliant pneumatic actuators possess many characteristics that are desirable for wearable robotic systems. These actuators can be lightweight, integrated with clothing, and accommodate uncontrolled degrees of freedom. These attributes are especially desirable for hand exoskeletons, where the soft actuator can conform to the highly variable digit shape. In particular, locating the pneumatic actuator on the palmar side of the digit may have benefits for assisting finger extension and resisting unwanted finger flexion, but this configuration requires suppleness to allow digit flexion while retaining sufficient stiffness to assist extension.

methodsTo meet these needs, we designed an actuator consisting of a hollow chamber long enough to span the joints of each digit while sufficiently narrow not to inhibit finger adduction. We explored the geometrical design parameter space for this chamber in terms of shape, dimensions, and wall thickness. After fabricating an elastomer-based prototype for each actuator design, we measured active extension force and passive resistance to bending for each chamber using a mechanical jig. We also created a finite element model for each chamber to enable estimation of the impact of chamber deformation, caused by joint rotation, on airflow through the chamber. Finally, we created a prototype hand exoskeleton with the chamber parameters yielding the best outcomes.

resultsA rectangular cross-sectional area was preferable to a semi-obround shape for the chamber; wall thickness also impacted performance. Extension joint torque reached 0.33 N-m at a low chamber pressure of 48.3 kPa. The finite element model confirmed that airflow for the rectangular chamber remained high despite deformation resulting from joint rotation. The hand exoskeleton created with the rectangular chambers enabled rapid movement, with a cycle time of 1.1 s for voluntary flexion followed by actuated extension.

conclusionsThe developed soft actuators are feasible for use in promoting finger extension from the palmar side of the hand. This placement utilizes pushing rather than pulling for digit extension, which is more comfortable and safer. The small chamber volumes allow rapid filling and evacuation to facilitate relatively high frequency finger movements.

Indexed as

Equipment DesignExoskeleton DeviceFingersRoboticsBiomechanical PhenomenaFinite Element AnalysisHumansWearable Electronic DevicesExtensionHandPneumatic actuatorsSoft exoskeleton

Identifiers

PMID39210475
PMCPMC11363593

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.