Evidence map›Paper›PMID 39207664›Full record

ArticleSleep & breathing = Schlaf & Atmung2024

Study on OSA screening and influencing factors in community-based elderly hypertensive patients based on single-lead wearable ECG devices.

Xinyan Yu, Linger Guan, Peng Su, Qinghong Zhang, Xuan Guo, Ting Li, Jing Zhang, Yongli Ji, Haicheng Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xinyan Yu *The First People's Hospital of Yinchuan, Yinchuan, Ningxia Hui Autonomous Region, China.
Linger Guan *Department of Cardiology, Peking University People's Hospital, Beijing, China.
Peng SuSchool of public health, North China University of Science and Technology, Tang Shan city, Hebei Province, China.
Qinghong ZhangLijing Yaju Community Health Service Station, The First People's Hospital of Yinchuan, Yinchuan City, Ningxia Hui Autonomous Region, China.
Xuan GuoNinghua Road Community Health Service Center, Yinchuan City, Ningxia Hui Autonomous Region, China.
Ting LiDaba Town Health Center, Qingtongxia City, Ningxia Hui Autonomous Region, China.
Jing ZhangYingshuiqiao Town Health Center, Shapotou District, Zhongwei City, Ningxia Hui Autonomous Region, China.
Yongli JiJingyuan Community Health Service Station, Shizuishan City, Ningxia Hui Autonomous Region, China.
Haicheng ZhangDepartment of Cardiology, Peking University People's Hospital, Beijing, China. haichengzhang@bjmu.edu.cn.ORCID 0000-0001-9655-9578

Funding

major projects of the National Social Science Fund 18ZDA086-4major special projects for scientific and technological innovation in Yinchua 2021-SF-009
6 · The paper itself

Abstract

purposeAssessing whether single-lead ECG can be effectively and relatively inexpensively used in large-scale OSA screening, and identifying factors influencing moderate-to-severe OSA among elderly hypertensive patients without atypical symptoms in primary care.

methodsThe study gathered data from 15 medical institutions in Ningxia between January and December 2022 using cloud platforms. The dataset included basic information and 72-h ECG monitoring for 2573 hypertensive patients over 65. OSA screening was conducted using the single-lead wearable ECG devices based on the ACAT algorithm. A multivariable logistic regression identified the main factors affecting OSA severity in these patients, and the AUC was used to assess the model's predictive accuracy.

resultsThe study found an OSA detection rate of 87.10%, with 55.42% being moderate to severe cases. Key risk factors associated with developing moderate-to-severe OSA included cardiac irregularities like supraventricular extrasystole and atrioventricular block, male gender, lifestyle factors like alcohol consumption and smoking, and health indicators such as SDNN ≤ 100 ms, abnormal LF/HF ratio, BMI, and age. The model's accuracy for predicting OSA, indicated by a ROAUC of 0.625, was moderate. Factors like gender, tea consumption, stroke history, and ventricular tachycardia were also independently linked to OSA severity.

conclusionThis study combines single-lead wearable ECG devices with the ACAT algorithm for OSA screening in Ningxia, China. Initial screening identified 87.10% of participants as having OSA, with 55.42% being moderate to severe cases. This suggests a convenient, low-cost, and repeatable ECG-based method for OSA screening, potentially improving early detection and management of OSA by identifying potential risk factors.

Indexed as

ElectrocardiographyHypertensionSleep Apnea, ObstructiveWearable Electronic DevicesAgedAged, 80 and overChinaFemaleHumansMaleMass ScreeningRisk FactorsHypertension in the elderlyInfluencing factorsObstructive sleep apnea–hypopnea syndromeScreeningSingle-lead wearable electrocardiographic devices

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.