ArticleFrontiers in physiology2024
Muscle reoxygenation is slower after higher cycling intensity, and is faster and more reliable in locomotor than in accessory muscle sites.
Article in Frontiers in physiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Post-Exercise Controlled Breathing Enhances Cardiovascular Recovery and Autonomic Balance: A Randomised Crossover Study.Medicina (Kaunas, Lithuania) · 2026Trial
- Integrating mechanical, physiological, and muscle oxygenation responses during field-based tethered repeated-sprint exercise in male professional soccer players.Physiological reports · 2026Article
- Skeletal Muscle Blood Flow and NIRS Oxygenation Kinetics as a Tool to Evaluate Adaptations to High-Intensity Exercise Training.Sensors (Basel, Switzerland) · 2026Article
- Agreement between muscle saturation breakpoints and lactate thresholds: Muscles comparison and sex difference in world-class Nordic skiers.Experimental physiology · 2026Article
- Validation of muscle oxygenation kinetics to predict aerobic fitness and exercise transition thresholds.Experimental physiology · 2026Article
- The overload loop: a distinct reoxygenation pattern above the second ventilatory threshold revealed by a new analytical method.Biology of sport · 2026Article
- Critical power and critical oxygenation: examining transferability between normoxia and hypoxia.European journal of applied physiology · 2025Article
- Effects of Compression Garments on Muscle Oxygen Saturation Recovery in the Upper Limbs Using Near-Infrared Spectroscopy.Journal of functional morphology and kinesiology · 2025Article
- Monitoring skeletal muscle oxygen saturation kinetics during graded exercise testing in NCAA division I female rowers.Frontiers in physiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Wearable near-infrared spectroscopy (NIRS) can be used during dynamic exercise to reflect the balance of muscle oxygen delivery and uptake. This study describes the behaviour and reliability of postexercise reoxygenation with NIRS as a function of exercise intensity at four muscle sites during an incremental cycling test. We discuss physiological components of faster and slower reoxygenation kinetics in the context of sport science and clinical applications. We hypothesised that reoxygenation would be slower at higher intensity, and that locomotor muscles would be faster than accessory muscles. We quantified test-retest reliability and agreement for each site. Methods: Twenty-one trained cyclists performed two trials of an incremental cycling protocol with 5-min work stages and 1-min rest between stages. NIRS was recorded from the locomotor vastus lateralis and rectus femoris muscles, and accessory lumbar paraspinal and lateral deltoid muscles. Reoxygenation time course was analysed as the half-recovery time (HRT) from the end of work to half of the peak reoxygenation amplitude during rest. Coefficient of variability (CV) between participants, standard error of the measurement (SEM) within participants, and intraclass correlation coefficient (ICC) for test-retest reliability were evaluated at 50%, 75%, and 100% peak workloads. A linear mixed-effects model was used to compare differences between workloads and muscle sites. Results: HRT was slower with increasing workload in the VL, RF, and PS, but not DL. VL had the fastest reoxygenation (lowest HRT) across muscle sites at all workloads (HRT = 8, 12, 17 s at 50%, 75%, 100% workload, respectively). VL also had the greatest reliability and agreement. HRT was sequentially slower between muscle sites in the order of VL < RF < PS < DL, and reliability was lower than for the VL. Discussion: This study highlights the potential for using wearable NIRS on multiple muscle sites during exercise. Reoxygenation kinetics differ between local muscle sites with increasing intensity. Moderate-to-good reliability in the VL support its increasing use in sport science and clinical applications. Lower reliability in other muscle sites suggest they are not appropriate to be used alone, but may add information when combined to better reflect systemic intensity and fatigue during exercise at different intensities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.