Evidence map›Paper›PMID 39206292›Full record

ArticleFrontiers in neurology2024

Flow diversion for unruptured MCA bifurcation aneurysms: comparison of p64 classic, p64 MW HPC, and p48 MW HPC flow diverter stents.

V Hellstern, N Brenner, A Cimpoca, P Albina Palmarola, E Henkes, C Wendl, H Bäzner, O Ganslandt, H Henkes

Abstract read
In one paragraph

Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

V HellsternNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
N BrennerNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
A CimpocaNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
P Albina PalmarolaNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
E HenkesNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
C WendlInstitut für Röntgendiagnostik, Zentrum für Neuroradiologie, Universitätsklinikum Regensburg, Regensburg, Germany.
H BäznerNeurologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
O GanslandtNeurochirurgische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
H HenkesNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: MCA bifurcation aneurysms pose treatment challenges because of the complex hemodynamics at the bifurcation and the risk of rupture. FDS implantation has been controversial and there are only limited reports. Therefore, the aim of this study was to assess the efficacy and safety of this treatment strategy using p64 MW HPC and p48 MW HPC FDSs for MCA bifurcation aneurysms, compared with the p64 classic FDS. Materials and methods: We retrospectively analyzed our institutional database and identified all patients with saccular, non-ruptured MCA bifurcation aneurysms treated with p64 MW HPC, p48 MW HPC, or p64 classic FDS implantation alone. Aneurysms with implantation of additional devices in the same session, previous treatments, and acutely ruptured and fusiform aneurysms were excluded. Results: A total of 79 aneurysms met the inclusion criteria: 23 receiving a p64 MW HPC, 34 receiving a p48 MW HPC, and 22 receiving a p64 classic FDS. The occlusion rate was highest for the p48 MW HPC 2 mm FDS, at 88.9% at FU2, compared with 72.2% for the p64 MW HPC and 70.6% for the p64 classic. The time to aneurysm occlusion was shortest with the p64 MW HPC, at 178.31 days. The highest retreatment rate was observed with the p48 MW HPC 3 mm. Conclusion: Treatment of MCA bifurcation aneurysms with a p48 MW HPC 2 mm or p64 MW HPC FDS is a safe and reliable strategy achieving high aneurysm occlusion rates - attributable to their lower porosity in relation to the parent vessel diameter as compared to the p48 MW HPC 3 mm FDS-, with reasonable morbidity and mortality.

Indexed as

DAPTflow diversionHPCMCA bifurcation aneurysmSAPT

Identifiers

PMID39206292
PMCPMC11349692

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.