ArticleFrontiers in neurology2024
Flow diversion for unruptured MCA bifurcation aneurysms: comparison of p64 classic, p64 MW HPC, and p48 MW HPC flow diverter stents.
Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Non-Ischemic Cerebral Enhancing (NICE) lesions after flow diversion for intracranial aneurysms: a systematic review with case-level synthesis.BMC neurology · 2026Pooled it
- Comparison of flow diverters versus stent-assisted coiling in unruptured anterior circulation bifurcation aneurysms: a two-center, propensity score matched study.Neurosurgical review · 2026Article
- Perforator-Sparing Microsurgical Clipping of Tandem Dominant-Hemisphere Middle Cerebral Artery Aneurysms: Geometry-Guided Reconstruction of a Wide-Neck Bifurcation and Dorsal M1 Fusiform Lesion.Diagnostics (Basel, Switzerland) · 2025Article
- Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.Clinical neuroradiology · 2025Article
- Efficacy and safety of p48 flow diverters in the treatment of intracranial aneurysms: A systematic review and Meta-Analysis.Neuroradiology · 2025Review
- Intracranial Aneurysms Treated with a Novel Coated Low-Profile Flow Diverter (p48 HPC)-A Single-Center Experience and an Illustrative Case Series.Brain sciences · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: MCA bifurcation aneurysms pose treatment challenges because of the complex hemodynamics at the bifurcation and the risk of rupture. FDS implantation has been controversial and there are only limited reports. Therefore, the aim of this study was to assess the efficacy and safety of this treatment strategy using p64 MW HPC and p48 MW HPC FDSs for MCA bifurcation aneurysms, compared with the p64 classic FDS. Materials and methods: We retrospectively analyzed our institutional database and identified all patients with saccular, non-ruptured MCA bifurcation aneurysms treated with p64 MW HPC, p48 MW HPC, or p64 classic FDS implantation alone. Aneurysms with implantation of additional devices in the same session, previous treatments, and acutely ruptured and fusiform aneurysms were excluded. Results: A total of 79 aneurysms met the inclusion criteria: 23 receiving a p64 MW HPC, 34 receiving a p48 MW HPC, and 22 receiving a p64 classic FDS. The occlusion rate was highest for the p48 MW HPC 2 mm FDS, at 88.9% at FU2, compared with 72.2% for the p64 MW HPC and 70.6% for the p64 classic. The time to aneurysm occlusion was shortest with the p64 MW HPC, at 178.31 days. The highest retreatment rate was observed with the p48 MW HPC 3 mm. Conclusion: Treatment of MCA bifurcation aneurysms with a p48 MW HPC 2 mm or p64 MW HPC FDS is a safe and reliable strategy achieving high aneurysm occlusion rates - attributable to their lower porosity in relation to the parent vessel diameter as compared to the p48 MW HPC 3 mm FDS-, with reasonable morbidity and mortality.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.