Evidence map›Paper›PMID 39205855›Full record

ArticleFrontiers in bioengineering and biotechnology2024

Characterizing thrombus adhesion strength on common cardiovascular device materials.

Vikas Kannojiya, Sara E Almasy, Jose L Monclova, Jerry Contreras, Francesco Costanzo, Keefe B Manning

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vikas KannojiyaDepartment of Biomedical Engineering, The Pennsylvania State University, University Park, PA, United States.
Sara E AlmasyDepartment of Biomedical Engineering, The Pennsylvania State University, University Park, PA, United States.
Jose L MonclovaDepartment of Biomedical Engineering, The Pennsylvania State University, University Park, PA, United States.
Jerry ContrerasDepartment of Biomedical Engineering, The Pennsylvania State University, University Park, PA, United States.
Francesco CostanzoDepartment of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, United States.
Keefe B ManningDepartment of Biomedical Engineering, The Pennsylvania State University, University Park, PA, United States.

Funding

Modeling of Acute Ischemic Stroke for Improving Mechanical ThrombectomyR01HL146921 · NHLBI · PENNSYLVANIA STATE UNIVERSITY, THE · PI Francesco Costanzo, Brent Craven · 2020 to 2026
$3.3M
NHLBI NIH HHS R01 HL146921
6 · The paper itself

Abstract

Thrombus formation in blood-contacting medical devices is a major concern in the medical device industry, limiting the clinical efficacy of these devices. Further, a locally formed clot within the device has the potential to detach from the surface, posing a risk of embolization. Clot embolization from blood-contacting cardiovascular devices can result in serious complications like acute ischemic stroke and myocardial infarction. Therefore, clot embolization associated with device-induced thrombosis can be life-threatening and requires an enhanced fundamental understanding of embolization characteristics to come up with advanced intervention strategies. Therefore, this work aims to investigate the adhesive characteristics of blood clots on common biocompatible materials used in various cardiovascular devices. This study focuses on characterizing the adhesion strength of blood clots on materials such as polytetrafluoroethylene (PTFE), polyurethane (PU), polyether ether ketone (PEEK), nitinol, and titanium, frequently used in medical devices. In addition, the effect of incubation time on clot adhesion is explored. Results from this work demonstrated strongest clot adhesion to titanium with 3 h of incubation resulting in 1.06 ± 0.20 kPa detachment stresses. The clot adhesion strength on titanium was 51.5% higher than PEEK, 35.9% higher than PTFE, 63.1% higher than PU, and 35.4% higher than nitinol. Further, adhesion strength increases with incubation time for all materials. The percentage increase in detachment stress over incubation time (ranging from 30 min to 3 h) for polymers ranged from at least 108.75% (PEEK), 140.74% (PU), to 151.61% (PTFE). Whereas, for metallic surfaces, the percentage rise ranged from 70.21% (nitinol) to 89.28% (titanium). Confocal fluorescence imaging of clot remnants on the material surfaces revealed a well-bounded platelet-fibrin network at the residual region, representing a comparatively higher adhesive region than the non-residual zone of the surface.

Indexed as

adhesionblood clotcardiovascular medical devicesembolizationnitinolpolymersstresstitanium

Identifiers

PMID39205855
PMCPMC11349534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.