Evidence map›Paper›PMID 39205827›Full record

ArticlePractical laboratory medicine2024

Analytical performances of a novel fluorescent immunoassay of anti-Müllerian hormone and establishment of the reference intervals in Chinese children.

Li Li, Mingyi Li, Wenqian Zhu, Lisong Shen, Limin Jiang

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Li LiDepartment of Clinical Laboratory, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Mingyi LiDepartment of Clinical Laboratory, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Wenqian ZhuDepartment of Clinical Laboratory, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Lisong ShenDepartment of Clinical Laboratory, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Limin JiangDepartment of Clinical Laboratory, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: AMH is important in child growth and the concentrations change with age and gender. This study aimed to evaluate the performance of the Pylon AMH assays and establish pediatric reference intervals. Methods: The experiments on imprecision, sensitivity, linearity, reportable range, interference and comparison were carried out to evaluate the analytical performance. The AMH reference ranges were calculated in 238 females and 346 males aged 0-18 years using robust methods. Results: The repeatability and the within-laboratory imprecision CVs of the assay were 3.7 % and 6.4 % at 2.25 ng/mL, and 4.6 % and 6.4 % at 15.49 ng/mL, respectively. The sensitivity (LoB = 0.05 ng/mL, LoD = 0.1 ng/mL and LoQ = 0.3 ng/mL) was verified. The linearity was 0.1-19.55 ng/mL and report up to 391 ng/mL with 20x pre-dilution. There was no significant interference from hemoglobin (500 mg/dL), triglyceride (500 mg/dL), bilirubin (10 mg/dL), cholesterol (800 mg/dL) and biotin (3000 ng/mL). The AMH measured by the Pylon assays correlated to those measured by the Elecsys assays. In males, the AMH levels were high at birth (0 d-1 m: median 95.10 ng/mL) and increased to a peak (7 m-1y: median 158.80 ng/mL) before they decreased with age (15-18 y: median 6.31 ng/mL). In females, the AMH concentrations were low at birth (0 d-1 m: median 0.20 ng/mL) and increased with age (15-18 y: median 3.03 ng/mL). Conclusion: The Pylon AMH assays showed good analytical performance and the AMH reference intervals in chinese children determined may provide a basis in clinical diagnosis and treatment of related diseases.

Indexed as

AMHAnalytical performanceFluorescent immunoassayPediatricsReference interval

Identifiers

PMID39205827
PMCPMC11350448

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.