ArticlePractical laboratory medicine2024
Analytical performances of a novel fluorescent immunoassay of anti-Müllerian hormone and establishment of the reference intervals in Chinese children.
Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Establishing reference intervals for serum glutathione reductase in healthy adults.Archives of medical science : AMS · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: AMH is important in child growth and the concentrations change with age and gender. This study aimed to evaluate the performance of the Pylon AMH assays and establish pediatric reference intervals. Methods: The experiments on imprecision, sensitivity, linearity, reportable range, interference and comparison were carried out to evaluate the analytical performance. The AMH reference ranges were calculated in 238 females and 346 males aged 0-18 years using robust methods. Results: The repeatability and the within-laboratory imprecision CVs of the assay were 3.7 % and 6.4 % at 2.25 ng/mL, and 4.6 % and 6.4 % at 15.49 ng/mL, respectively. The sensitivity (LoB = 0.05 ng/mL, LoD = 0.1 ng/mL and LoQ = 0.3 ng/mL) was verified. The linearity was 0.1-19.55 ng/mL and report up to 391 ng/mL with 20x pre-dilution. There was no significant interference from hemoglobin (500 mg/dL), triglyceride (500 mg/dL), bilirubin (10 mg/dL), cholesterol (800 mg/dL) and biotin (3000 ng/mL). The AMH measured by the Pylon assays correlated to those measured by the Elecsys assays. In males, the AMH levels were high at birth (0 d-1 m: median 95.10 ng/mL) and increased to a peak (7 m-1y: median 158.80 ng/mL) before they decreased with age (15-18 y: median 6.31 ng/mL). In females, the AMH concentrations were low at birth (0 d-1 m: median 0.20 ng/mL) and increased with age (15-18 y: median 3.03 ng/mL). Conclusion: The Pylon AMH assays showed good analytical performance and the AMH reference intervals in chinese children determined may provide a basis in clinical diagnosis and treatment of related diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.