ArticleSensors (Basel, Switzerland)2024
Performance Study of F-P Pressure Sensor Based on Three-Wavelength Demodulation: High-Temperature, High-Pressure, and High-Dynamic Measurements.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
F-P (Fabry-Perot) pressure sensors have a wide range of potential applications in high-temperature, high-pressure, and high-dynamic environments. However, existing demodulation methods commonly rely on spectrometers, which limits their application to high-frequency pressure signal acquisition. To solve this problem, this study developed a self-compensated, three-wavelength demodulation system composite with an F-P pressure sensor and a thermocouple to construct a comprehensive sensing system. The system produces accurate pressure measurements in high-temperature, high-pressure, and high-dynamic environments. In static testing at room temperature, the sensing system shows excellent linearity, and the pressure sensitivity is 158.48 nm/MPa. In high-temperature testing, the sensing system maintains high linearity in the range of 100 °C to 700 °C, with a maximum pressure-indication error of about 0.13 MPa (0~5 MPa). In dynamic testing, the sensor exhibits good response characteristics at 1000 Hz and 5000 Hz sinusoidal pressure frequencies, with a signal-to-noise ratio (SNR) greater than 37 dB and 45 dB, respectively. These results indicate that the sensing system proposed in this study has significant competitive advantages in the field of high-temperature, high-speed, and high-precision pressure measurements and provides an important experimental basis and theoretical support for technological progress in related fields.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.