Evidence map›Paper›PMID 39204996›Full record

ArticleSensors (Basel, Switzerland)2024

Design of Three-Dimensional Magnetic Probe System for Space Plasma Environment Research Facility (SPERF).

Jihua Yang, Jiayin Xie, Wenbin Ling, Jian Guan, Kai Huang, Fupeng Chen, Gaoyuan Peng, Huibo Tang, Hua Zhou, Peng E

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jihua YangCollege of Big Data and Information Engineering, Guizhou University, Guiyang 550025, China.
Jiayin XieLaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.
Wenbin LingLaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.
Jian GuanLaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.
Kai HuangSchool of Physics, Harbin Institute of Technology, Harbin 150001, China.
Fupeng ChenLaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.
Gaoyuan PengLaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.
Huibo TangSchool of Physics, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0003-3039-164X
Hua ZhouCollege of Big Data and Information Engineering, Guizhou University, Guiyang 550025, China.
Peng ELaboratory for Space Environment and Physical sciences, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-8731-3055

Funding

National Key Laboratory of Space Environment and Matter Behaviors 2023-JCJQ-LB-059National Natural Science Foundation of China (NSFC) 12205298the China Postdoctoral Science Foundation 2018M631918the National Key Research and Development Program of China 2022YFA1604600the National Natural Science Foundation of China 11705039
6 · The paper itself

Abstract

A three-dimensional magnetic probe system has been designed and implemented at the Space Plasma Environment Research Facility (SPERF). This system has been developed to measure the magnetic field with high spatial and temporal resolution, enabling studies of fundamental processes in space physics, such as magnetic reconnection at the Earth's magnetopause, on the basis of SPERF. The system utilizes inductive components as sensors, arranged in an array and soldered onto a printed circuit board (PCB), achieving a spatial resolution of 2.5 mm. The system's electrical parameters have been measured, and its amplitude-frequency response characteristics have been simulated. The system has demonstrated good performance with response capabilities below 50 kHz. The experimental setup and results are discussed, highlighting the system's effectiveness in accurately measuring weak magnetic signals and its suitability for magnetic reconnection experiments.

Indexed as

magnetic measurementmagnetic probemagnetic reconnectionplasma diagnostics

Identifiers

PMID39204996
PMCPMC11359541

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.