ArticleSensors (Basel, Switzerland)2024
Pointer Meter Reading Method Based on YOLOv8 and Improved LinkNet.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In order to improve the reading efficiency of pointer meter, this paper proposes a reading method based on LinkNet. Firstly, the meter dial area is detected using YOLOv8. Subsequently, the detected images are fed into the improved LinkNet segmentation network. In this network, we replace traditional convolution with partial convolution, which reduces the number of model parameters while ensuring accuracy is not affected. Remove one pair of encoding and decoding modules to further compress the model size. In the feature fusion part of the model, the CBAM (Convolutional Block Attention Module) attention module is added and the direct summing operation is replaced by the AFF (Attention Feature Fusion) module, which enhances the feature extraction capability of the model for the segmented target. In the subsequent rotation correction section, this paper effectively addresses the issue of inaccurate prediction by CNN networks for axisymmetric images within the 0-360° range, by dividing the rotation angle prediction into classification and regression steps. It ensures that the final reading part receives the correct angle of image input, thereby improving the accuracy of the overall reading algorithm. The final experimental results indicate that our proposed reading method has a mean absolute error of 0.20 and a frame rate of 15.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.