Evidence map›Paper›PMID 39204961›Full record

ArticleSensors (Basel, Switzerland)2024

Real-Time Sensing of Upper Extremity Movement Diversity Using Kurtosis Implemented on a Smartwatch.

Guillem Cornella-Barba, Shusuke Okita, Zheng Li, David J Reinkensmeyer

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Guillem Cornella-BarbaDepartment of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA.ORCID 0009-0000-1300-7533
Shusuke OkitaMax Näder Center for Rehabilitation Technologies and Outcomes Research, Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL 60611, USA.ORCID 0000-0001-8041-9220
Zheng LiSchool of Electronics, Electrical Engineering and Computer Science, Queen's University Belfast, Belfast BT7 1NN, UK.ORCID 0000-0002-9704-7651
David J ReinkensmeyerDepartment of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA.ORCID 0000-0002-3196-8706

Funding

ACL HHS 90REGE0005
6 · The paper itself

Abstract

Wearable activity sensors typically count movement quantity, such as the number of steps taken or the number of upper extremity (UE) counts achieved. However, for some applications, such as neurologic rehabilitation, it may be of interest to quantify the quality of the movement experience (QOME), defined, for example, as how diverse or how complex movement epochs are. We previously found that individuals with UE impairment after stroke exhibited differences in their distributions of forearm postures across the day and that these differences could be quantified with kurtosis-an established statistical measure of the peakedness of distributions. In this paper, we describe further progress toward the goal of providing real-time feedback to try to help people learn to modulate their movement diversity. We first asked the following: to what extent do different movement activities induce different values of kurtosis? We recruited seven unimpaired individuals and evaluated a set of 12 therapeutic activities for their forearm postural diversity using kurtosis. We found that the different activities produced a wide range of kurtosis values, with conventional rehabilitation therapy exercises creating the most spread-out distribution and cup stacking the most peaked. Thus, asking people to attempt different activities can vary movement diversity, as measured with kurtosis. Next, since kurtosis is a computationally expensive calculation, we derived a novel recursive algorithm that enables the real-time calculation of kurtosis. We show that the algorithm reduces computation time by a factor of 200 compared to an optimized kurtosis calculation available in SciPy, across window sizes. Finally, we embedded the kurtosis algorithm on a commercial smartwatch and validated its accuracy using a robotic simulator that "wore" the smartwatch, emulating movement activities with known kurtosis. This work verifies that different movement tasks produce different values of kurtosis and provides a validated algorithm for the real-time calculation of kurtosis on a smartwatch. These are needed steps toward testing QOME-focused, wearable rehabilitation.

Indexed as

AlgorithmsMovementUpper ExtremityWearable Electronic DevicesAdultFemaleHumansMalePostureStroke Rehabilitationaccelerometerkurtosisrehabilitationrolling statisticstilt sensingupper extremity movement diversitywearable activity sensing

Identifiers

PMID39204961
PMCPMC11358890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.