ArticleSensors (Basel, Switzerland)2024
Off-Axis Integral Cavity Carbon Dioxide Gas Sensor Based on Machine-Learning-Based Optimization.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- AI‑driven photonic noses: from conventional sensors to cloud‑to-edge intelligent microsystems.Microsystems & nanoengineering · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurately detecting atmospheric carbon dioxide is a vital part of responding to the global greenhouse effect. Conventional off-axis integral cavity detection systems are computationally intensive and susceptible to environmental factors. This study deploys an Extreme Learning Machine model incorporating a cascaded integrator comb (CIC) filter into the off-axis integrating cavity. It is shown that appropriate parameters can effectively improve the performance of the instrument in terms of lower detection limit, accuracy, and root mean square deviation. The proposed method is incorporated successfully into a monitoring station situated near an industrial area for detecting atmospheric carbon dioxide (CO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.