Evidence map›Paper›PMID 39204921›Full record

ArticleSensors (Basel, Switzerland)2024

Defect Detection of GFRP Composites through Long Pulse Thermography Using an Uncooled Microbolometer Infrared Camera.

Murniwati Anwar, Faizal Mustapha, Mohd Na'im Abdullah, Mazli Mustapha, Nabihah Sallih, Azlan Ahmad, Siti Zubaidah Mat Daud

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Murniwati AnwarDepartment of Mechanical Engineering, University Kuala Lumpur Malaysia France Institute (UniKL-MFI), Bandar Baru Bangi 43650, Malaysia.ORCID 0000-0001-5122-9292
Faizal MustaphaDepartment of Aerospace Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID 0000-0002-0191-1653
Mohd Na'im AbdullahDepartment of Aerospace Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.ORCID 0000-0001-8498-1560
Mazli MustaphaDepartment of Mechanical Engineering, Universiti Teknologi Petronas, Seri Iskandar 32610, Malaysia.
Nabihah SallihDepartment of Mechanical Engineering, Universiti Teknologi Petronas, Seri Iskandar 32610, Malaysia.
Azlan AhmadDepartment of Mechanical Engineering, Universiti Teknologi Petronas, Seri Iskandar 32610, Malaysia.ORCID 0000-0001-6289-5442
Siti Zubaidah Mat DaudLANL-JBNU Engineering Institute-Korea, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea.ORCID 0000-0003-0614-7372

Funding

Yayasan Universiti Teknologi PETRONAS YUTP-FRG-015LC0-417
6 · The paper itself

Abstract

The detection of impact and depth defects in Glass Fiber Reinforced Polymer (GFRP) composites has been extensively studied to develop effective, reliable, and cost-efficient assessment methods through various Non-Destructive Testing (NDT) techniques. Challenges in detecting these defects arise from varying responses based on the geometrical shape, thickness, and defect types. Long Pulse Thermography (LPT), utilizing an uncooled microbolometer and a low-resolution infrared (IR) camera, presents a promising solution for detecting both depth and impact defects in GFRP materials with a single setup and minimal tools at an economical cost. Despite its potential, the application of LPT has been limited due to susceptibility to noise from environmental radiation and reflections, leading to blurry images. This study focuses on optimizing LPT parameters to achieve accurate defect detection. Specifically, we investigated 11 flat-bottom hole (FBH) depth defects and impact defects ranging from 8 J to 15 J in GFRP materials. The key parameters examined include the environmental temperature, background reflection, background color reflection, and surface emissivity. Additionally, we employed image processing techniques to classify composite defects and automatically highlight defective areas. The Tanimoto Criterion (TC) was used to evaluate the accuracy of LPT both for raw images and post-processed images. The results demonstrate that through parameter optimization, the depth defects in GFRP materials were successfully detected. The TC success rate reached 0.91 for detecting FBH depth defects in raw images, which improved significantly after post-processing using Canny edge detection and Hough circle detection algorithms. This study underscores the potential of optimized LPT as a cost-effective and reliable method for detecting defects in GFRP composites.

Indexed as

defectGFRPimpactIR cameralong pulse thermography (LPT)uncooled microbolometer

Identifiers

PMID39204921
PMCPMC11359281

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.