Evidence map›Paper›PMID 39204836›Full record

ArticleSensors (Basel, Switzerland)2024

Investigations into the Geometric Calibration and Systematic Effects of a Micro-CT System.

Matthias Hardner, Frank Liebold, Franz Wagner, Hans-Gerd Maas

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matthias HardnerInstitute of Photogrammetry and Remote Sensing, TUD Dresden University of Technology, 01069 Dresden, Germany.ORCID 0009-0007-1588-117X
Frank LieboldInstitute of Photogrammetry and Remote Sensing, TUD Dresden University of Technology, 01069 Dresden, Germany.ORCID 0000-0001-5649-6461
Franz WagnerInstitute of Photogrammetry and Remote Sensing, TUD Dresden University of Technology, 01069 Dresden, Germany.ORCID 0000-0002-0715-6118
Hans-Gerd MaasInstitute of Photogrammetry and Remote Sensing, TUD Dresden University of Technology, 01069 Dresden, Germany.ORCID 0000-0001-9034-3469

Funding

Deutsche Forschungsgemeinschaft 417002380
6 · The paper itself

Abstract

Micro-Computed Tomography (µCT) systems are used for examining the internal structures of various objects, such as material samples, manufactured parts, and natural objects. Resolving fine details or performing accurate geometric measurements in the voxel data critically depends on the precise calibration of the µCT systems geometry. This paper presents a calibration method for µCT systems using projections of a calibration phantom, where the coordinates of the phantom are initially unknown. The approach involves detecting and tracking steel ball bearings and adjusting the unknown system geometry parameters using non-linear least squares optimization. Multiple geometric models are tested to verify their suitability for a self-calibration approach. The implementation is tested using a calibration phantom captured at different magnifications. The results demonstrate the system's capability to determine the geometry model parameters with a remaining error on the detector between 0.27 px and 0.18 px. Systematic errors that remain after calibration, as well as changing parameters due to system instabilities, are investigated. The source code of this work is published to enable further research.

Indexed as

instrument geometrymeasurement uncertaintysystem calibrationX-ray computed tomography

Identifiers

PMID39204836
PMCPMC11360169

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked