Evidence map›Paper›PMID 39204820›Full record

ArticleSensors (Basel, Switzerland)2024

Temperature Compensation Method Based on Bilinear Interpolation for Downhole High-Temperature Pressure Sensors.

Yizhan Shu, Chenquan Hua, Zerun Zhao, Pengcheng Wang, Haocheng Zhang, Wenxin Yu, Haobo Yu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yizhan ShuCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
Chenquan HuaCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.ORCID 0000-0002-4208-2628
Zerun ZhaoCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
Pengcheng WangCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
Haocheng ZhangCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
Wenxin YuCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
Haobo YuCollege of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.

Funding

Key R&D Program of Shandong Province, China 2019GHZ001
6 · The paper itself

Abstract

Due to their high accuracy, excellent stability, minor size, and low cost, silicon piezoresistive pressure sensors are used to monitor downhole pressure under high-temperature, high-pressure conditions. However, due to silicon's temperature sensitivity, high and very varied downhole temperatures cause a significant bias in pressure measurement by the pressure sensor. The temperature coefficients differ from manufacturer to manufacturer and even vary from batch to batch within the same manufacturer. To ensure high accuracy and long-term stability for downhole pressure monitoring at high temperatures, this study proposes a temperature compensation method based on bilinear interpolation for piezoresistive pressure sensors under downhole high-temperature and high-pressure environments. A number of calibrations were performed with high-temperature co-calibration equipment to obtain the individual temperature characteristics of each sensor. Through the calibration, it was found that the output of the tested pressure measurement system is positively linear with pressure at the same temperatures and nearly negatively linear with temperature at the same pressures, which serves as the bias correction for the subsequent bilinear interpolation temperature compensation method. Based on this result, after least squares fitting and interpolating, a bilinear interpolation approach was introduced to compensate for temperature-induced pressure bias, which is easier to implement in a microcontroller (MCU). The test results show that the proposed method significantly improves the overall measurement accuracy of the tested sensor from 21.2% F.S. to 0.1% F.S. In addition, it reduces the MCU computational complexity of the compensation model, meeting the high accuracy demand for downhole pressure monitoring at high temperatures and pressures.

Indexed as

bilinear interpolationhigh temperatureleast squarepiezoresistive pressure sensortemperature compensation

Identifiers

PMID39204820
PMCPMC11359658

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked