Evidence map›Paper›PMID 39204819›Full record

ArticleSensors (Basel, Switzerland)2024

Compact Chromatic Confocal Lens with Large Measurement Range.

Ning He, Huiqin Hu, Zhiying Cui, Xinjun Xu, Dakai Zhou, Yunbo Chen, Puyin Gong, Youhua Chen, Cuifang Kuang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ning HeNingbo Research Institute, Zhejiang University, Ningbo 315100, China.
Huiqin HuNingbo Research Institute, Zhejiang University, Ningbo 315100, China.ORCID 0009-0000-6930-5476
Zhiying CuiNingbo Yongxin Optics Co., Ltd., Ningbo 315048, China.
Xinjun XuNingbo Research Institute, Zhejiang University, Ningbo 315100, China.
Dakai ZhouNingbo Research Institute, Zhejiang University, Ningbo 315100, China.
Yunbo ChenNingbo Research Institute, Zhejiang University, Ningbo 315100, China.
Puyin GongNingbo Yongxin Optics Co., Ltd., Ningbo 315048, China.
Youhua ChenNingbo Research Institute, Zhejiang University, Ningbo 315100, China.ORCID 0000-0002-8766-4605
Cuifang KuangNingbo Research Institute, Zhejiang University, Ningbo 315100, China.

Funding

National Key Research and Development Program of China 2021YFF0700302National Natural Science Foundation of China 61975188National Science Fund for Distinguished Young Scholars 62125504Natural Science Foundation of Zhejiang Province LY23F050010
6 · The paper itself

Abstract

Spectral confocal sensors are effective for measuring displacements. The core of the spectral confocal measurement system is a dispersive objective lens that uses optical dispersion to establish a one-to-one correspondence between the focusing position and wavelength, achieving high-resolution measurements in the longitudinal direction. Despite significant progress in dispersive objective lenses for spectral confocal sensor systems, challenges such as a limited dispersion range, high cost, and insufficient measurement accuracy persist. To expand the measurement range and improve the accuracy of the spectral confocal sensor, we designed a compact, long-axial dispersion objective lens. This lens has a simple structure that requires only six lens elements, two of which form cemented doublets. The system length is 58 mm, with a working distance of 46 ± 6 mm and a dispersion range of 12 mm within the wavelength range of 450-656 nm. The lens has an object-side numerical aperture (NA) of 0.22 and an image-side NA between 0.198 and 0.24, ensuring high light energy utilization. Finally, a spectral confocal measurement system was constructed based on the designed dispersive objective lens, and performance evaluation tests were conducted. The test results showed that the system achieved a resolution of 0.15 μm and a maximum linear error of ±0.7 μm, demonstrating high-precision measurement capabilities. The proposed lens design enables the development of more portable and cost-effective spectral confocal sensors.

Indexed as

dispersive objective lensdisplacement sensorspectral confocal sensorspectrometer

Identifiers

PMID39204819
PMCPMC11359950

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.