ArticlePharmaceutics2024
Quantification of Microsphere Drug Release by Fluorescence Imaging with the FRET System.
Article in Pharmaceutics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Accurately measuring drug and its release kinetics in both in vitro and in vivo environments is crucial for enhancing therapeutic effectiveness while minimizing potential side effects. Nevertheless, the real-time visualization of drug release from microspheres to monitor potential overdoses remains a challenge. The primary objective of this investigation was to employ fluorescence imaging for the real-time monitoring of drug release from microspheres in vitro, thereby simplifying the laborious analysis associated with the detection of drug release. Two distinct varieties of microspheres were fabricated, each encapsulating different drugs within PLGA polymers. Cy5 was selected as the donor, and Cy7 was selected as the acceptor for visualization and quantification of the facilitated microsphere drug release through the application of the fluorescence resonance energy transfer (FRET) principle. The findings from the in vitro experiments indicate a correlation between the FRET fluorescence alterations and the drug release profiles of the microspheres.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.