Evidence map›Paper›PMID 39203710›Full record

ArticleMicromachines2024

Deep Learning-Assisted Smartphone-Based Electrochemiluminescence Visual Monitoring Biosensor: A Fully Integrated Portable Platform.

Manish Bhaiyya, Prakash Rewatkar, Amit Pimpalkar, Dravyansh Jain, Sanjeet Kumar Srivastava, Jitendra Zalke, Jayu Kalambe, Suresh Balpande, Pawan Kale, Yogesh Kalantri and 1 more

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Manish BhaiyyaDepartment Electronics Engineering, Ramdeobaba University, Nagpur 440013, India.ORCID 0000-0003-4442-3753
Prakash RewatkarDepartment of Mechanical Engineering, Israel Institute of Technology, Technion, Haifa 3200003, Israel.
Amit PimpalkarDepartment of Computer Science & Engineering, Ramdeobaba University, Nagpur 440013, India.ORCID 0000-0003-4281-6270
Dravyansh JainComputer Science & Information Systems, Birla Institute of Technology & Science Pilani, Hyderabad Campus, Hyderabad 500078, India.
Sanjeet Kumar SrivastavaDepartment of Electrical & Electronics Engineering, Birla Institute of Technology & Science Pilani, Hyderabad Campus, Hyderabad 500078, India.
Jitendra ZalkeDepartment Electronics Engineering, Ramdeobaba University, Nagpur 440013, India.ORCID 0000-0002-5382-3508
Jayu KalambeDepartment Electronics Engineering, Ramdeobaba University, Nagpur 440013, India.
Suresh BalpandeDepartment of Information Technology and Security, Ramdeobaba University, Nagpur 440013, India.ORCID 0000-0003-4514-5724
Pawan KaleFractal Analytics Private Limited, Pune 411045, India.
Yogesh KalantriCitco Shared Services Private Limited, Mumbai 400072, India.
Madhusudan B KulkarniDepartment of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA.ORCID 0000-0002-2911-3784

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A novel, portable deep learning-assisted smartphone-based electrochemiluminescence (ECL) cost-effective (~10$) sensing platform was developed and used for selective detection of lactate. Low-cost, fast prototyping screen printing and wax printing methods with paper-based substrate were used to fabricate miniaturized single-pair electrode ECL platforms. The lab-made 3D-printed portable black box served as a reaction chamber. This portable platform was integrated with a smartphone and a buck-boost converter, eliminating the need for expensive CCD cameras, photomultiplier tubes, and bulky power supplies. This advancement makes this platform ideal for point-of-care testing applications. Foremost, the integration of a deep learning approach served to enhance not just the accuracy of the ECL sensors, but also to expedite the diagnostic procedure. The deep learning models were trained (3600 ECL images) and tested (900 ECL images) using ECL images obtained from experimentation. Herein, for user convenience, an Android application with a graphical user interface was developed. This app performs several tasks, which include capturing real-time images, cropping them, and predicting the concentration of required bioanalytes through deep learning. The device's capability to work in a real environment was tested by performing lactate sensing. The fabricated ECL device shows a good liner range (from 50 µM to 2000 µM) with an acceptable limit of detection value of 5.14 µM. Finally, various rigorous analyses, including stability, reproducibility, and unknown sample analysis, were conducted to check device durability and stability. Therefore, the developed platform becomes versatile and applicable across various domains by harnessing deep learning as a cutting-edge technology and integrating it with a smartphone.

Indexed as

biosensordeep learningelectrochemiluminescencepoint-of-care testingvisual monitoring

Identifiers

PMID39203710
PMCPMC11356000

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.