Evidence map›Paper›PMID 39203689›Full record

ArticleMicromachines2024

The Performance and Fabrication of 3D Variable Cross-Section Channel for Passive Microfluidic Control.

Wenjie Qian, Zhou Zhou, Qing Wang, Wei Shi, Manman Xu, Daoheng Sun

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wenjie QianSchool of Mechanical and Automotive Engineering, Anhui Polytechnic University, Wuhu 241000, China.ORCID 0009-0007-0629-1135
Zhou ZhouSchool of Mechanical and Automotive Engineering, Anhui Polytechnic University, Wuhu 241000, China.ORCID 0000-0003-2799-516X
Qing WangSchool of Mechanical and Automotive Engineering, Anhui Polytechnic University, Wuhu 241000, China.
Wei ShiSchool of Mechanical and Automotive Engineering, Anhui Polytechnic University, Wuhu 241000, China.
Manman XuWuhu HIT Robot Industry Research Institute Co., Ltd., Wuhu 241000, China.
Daoheng SunSchool of Aeronautics and Astronaut, Xiamen University, Xiamen 361102, China.

Funding

Anhui Future Technology Research Institute Industry Guidance Fund Project 2023ccyd01Anhui Polytechnic University research start-up project No.2020YQQ029National Nature Science Foundation of China U2005214The authors acknowledge the support of the Natural Science Foundation of Anhui Province 2108085QE226
6 · The paper itself

Abstract

Passive fluid control has mostly been used for valves, pumps, and mixers in microfluidic systems. The basic principle is to generate localized losses in special channel structures, such as branches, grooves, or spirals. The flow field in two-dimensional space can be easily calculated using the typical Stokes formula, but it is challenging in three-dimensional space. Moreover, the flow field with periodic variable cross-sections channeled of polyhedral units has been neglected in this research field due to previous limitations in manufacturing technology. With the continuous progress of 3D printing technology, the field of microfluidic devices ushered in a new era of manufacturing three-dimensional irregular channels. In this study, we present finite analysis results for a periodic nodular-like channel. The experiments involve variations in the Reynold number (Re), periodic frequency, and comparative analyses with conventional structures. The findings indicate that this variable 3D cross-section structure can readily achieve performance comparable to other passive fluid control methods in valve applications. A 3D model of the periodic tetrahedron channel was fabricated using 3D printing to validate these conclusions. This research has the potential to significantly enhance the performance of passive fluid control units that have long been constrained by manufacturing dimensions.

Indexed as

3D printingdiodicityfinite analysismicrofluidicvariable cross-sections channel

Identifiers

PMID39203689
PMCPMC11356130

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.