Evidence map›Paper›PMID 39203613›Full record

ArticleMicromachines2024

Design of Acetaldehyde Gas Sensor Based on Piezoelectric Multilayer Microelectromechanical System Resonator.

Primavera Argüelles-Lucho, Rosa M Woo-García, Leandro García-González, Rene Pérez-Cuapio, Natiely Hernández-Sebastian, Agustín L Herrera-May, Francisco López-Huerta

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Primavera Argüelles-LuchoFacultad de Ingeniería de la Construcción y el Hábitat, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico.ORCID 0000-0002-3460-1838
Rosa M Woo-GarcíaFacultad de Ingeniería de la Construcción y el Hábitat, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico.
Leandro García-GonzálezMicro and Nanotechnology Research Center, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico.ORCID 0000-0002-0968-6745
Rene Pérez-CuapioFaculty of Chemical Engineering, Benemerite Autonomous University of Puebla, Puebla 72570, Puebla, Mexico.
Natiely Hernández-SebastianOptical Research Center, León 37150, Guanajuato, Mexico.ORCID 0000-0003-3800-9003
Agustín L Herrera-MayFacultad de Ingeniería de la Construcción y el Hábitat, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico.ORCID 0000-0002-7373-9258
Francisco López-HuertaFaculty of Electrical and Electronic Engineering, University Veracruzana, Boca del Río 94294, Veracruz, Mexico.ORCID 0000-0003-3332-846X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acetaldehyde is a volatile organic compound that can cause damage at the cellular and genomic levels. The monitoring of acetaldehyde gas at low concentrations requires fast-response and low-cost sensors. Herein, we propose the design of an acetaldehyde gas sensor based on a low-cost Microelectromechanical System (MEMS) process. This sensor is formed by a single-clamped piezoelectric multilayer resonator (3000 × 1000 × 52.2 µm) with a simple operating principle and easy signal processing. This resonator uses a zinc oxide piezoelectric layer (1 µm thick) and a sensing film of titanium oxide (1 µm thick). In addition, the resonator uses a support layer of 304 stainless steel (50 µm thick) and two aluminum layers (100 nm thick). Analytical and Finite-Element Method (FEM) models are developed to predict the mechanical behavior of the gas sensor, considering the influence of the different layers of the resonator. The analytical results agree well with respect to the FEM model results. The gas sensor has a first bending frequency of 4722.4 Hz and a sensitivity of 8.22 kHz/g. A minimum detectable concentration of acetaldehyde of 102 ppm can be detected with the proposed sensor. This gas sensor has a linear behavior to detect different acetaldehyde concentrations using the frequency shifts of its multilayer resonator. The gas sensor design offers advantages such as small size, a light weight, and cost-efficient fabrication.

Indexed as

acetaldehydegas sensorMEMSmultilayerpiezoelectricresonator