Robot-Assisted 2D Fluoroscopic Needle Placement-A Phantom Study.

Yannick Scharll, Nenad Radojicic, Gregor Laimer, Peter Schullian, Reto Bale

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Vision-based augmented reality guidance for setting up robot-assisted spine surgery.International journal of computer assisted radiology and surgery · 2026
    Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yannick ScharllInterventional Oncology-Stereotaxy & Robotics (SIP), Department of Radiology, Medical University Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria.
Nenad RadojicicInterventional Oncology-Stereotaxy & Robotics (SIP), Department of Radiology, Medical University Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria.
Gregor LaimerInterventional Oncology-Stereotaxy & Robotics (SIP), Department of Radiology, Medical University Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria.ORCID 0000-0002-6116-4901
Peter SchullianInterventional Oncology-Stereotaxy & Robotics (SIP), Department of Radiology, Medical University Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria.
Reto BaleInterventional Oncology-Stereotaxy & Robotics (SIP), Department of Radiology, Medical University Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria.ORCID 0000-0003-0021-5792

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

RATIONALE AND

objectivesTo evaluate the targeting accuracy of a novel robot-assisted guidance technique relying on one pair of 2D C-arm images. MATERIAL AND

methodsIn total, 160 punctures were carried out semi-automatically by using a novel robotic device. The needle's paths were planned based on one pair of 2D fluoroscopic images from different angles. Conically shaped aluminum tips inside a gelatin-filled plexiglass phantom served as targets. The accuracy of the needle placement was assessed by taking control CTs and measuring the Euclidean distance (ED) and normal distance (ND) between the needle and the target point. In addition, the procedural time per needle placement was evaluated.

resultsThe accomplished mean NDs at the target for the 45°, 60°, 75° and 90° angles were 1.86 mm (SD ± 0.19), 2.68 mm (SD ± 0.18), 2.19 mm (SD ± 0.18) and 1.86 mm (SD ± 0.18), respectively. The corresponding mean EDs were 2.32 mm (SD ± 0.16), 2.68 mm (SD ± 0.18), 2.65 mm (SD ± 0.16) and 2.44 mm (SD ± 0.15). The mean duration of the total procedure, including image acquisition, trajectory planning and placement of four needles sequentially, was 12.7 min.

conclusionsRobotic guidance based on two 2D fluoroscopy images allows for the precise placement of needle-like instruments at the first attempt without the need for using an invasive dynamic reference frame. This novel approach seems to be a valuable tool for the precise targeting of various anatomical structures that can be identified in fluoroscopic images.

Indexed as

fluoroscopyimaginginterventionalpuncturesroboticsrobotic surgical procedures

Identifiers

PMID39202211
PMCPMC11354198