ArticleNeurologia medico-chirurgica2024
Coil Embolization for Cerebral Aneurysm Using Low Pulse Rate Fluoroscopy.
Article in Neurologia medico-chirurgica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although coil embolization is commonly perceived as a minimally invasive procedure, the associated radiation exposure cannot be disregarded. To date, no specific study has investigated radiation exposure during coil embolization. This study aimed to investigate the potential of lowering the pulse rate to decrease radiation exposure during coil embolization while maintaining patient safety. Radiation data and clinical features of 70 patients who underwent coil embolization between 2015 and 2020 were retrospectively analyzed. Since July 2017, the pulse rate was regulated from 7.5 to 4 frames per second (f/s). Statistical analyses were performed to examine the correlation between pulse rate and radiation exposure. Out of the 70 procedures, 30 were performed at the standard pulse rate (7.5 f/s), and 40 were performed at the lower pulse rate (4 f/s). In the lower-pulse-rate group, the absorbed dose to the patient (AK) was 2580.7 (±217) mGy, whereas in the standard-pulse-rate group, it was 4760 (±411.1). Both the dose-area product (DAP) and AK were substantially reduced in the low pulse rate group (p = 0.000002). There was a significant correlation between DAP and AK and pulse rate (p = 0.004, p = 0.0017, respectively). Moreover, there was no significant correlation between pulse rate and perioperative complications. Our findings suggest that using a lower pulse rate (4 f/s) can effectively reduce radiation exposure during coil embolization for cerebral aneurysms while ensuring patient safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials