Evidence map›Paper›PMID 39196294›Full record

ArticleEuropean radiology experimental2024

Vessel-based CTA-image to spatial anatomy registration using tracked catheter position data: preclinical evaluation of in vivo accuracy.

Geir Arne Tangen, Petter Aadahl, Toril A N Hernes, Frode Manstad-Hulaas

Abstract read
In one paragraph

Article in European radiology experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Geir Arne TangenSINTEF Digital, Department of Health Research, Trondheim, Norway.
Petter AadahlDepartment of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
Toril A N HernesDepartment of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
Frode Manstad-HulaasNorwegian National Center for Minimally Invasive and Image-Guided Diagnostics and Therapy, St. Olavs Hospital, Trondheim, Norway. frode.manstad-hulaas@stolav.no.ORCID http://orcid.org/0000-0002-4899-0248

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electromagnetic tracking of endovascular instruments has the potential to substantially decrease radiation exposure of patients and personnel. In this study, we evaluated the in vivo accuracy of a vessel-based method to register preoperative computed tomography angiography (CTA) images to physical coordinates using an electromagnetically tracked guidewire. Centerlines of the aortoiliac arteries were extracted from preoperative CTA acquired from five swine. Intravascular positions were obtained from an electromagnetically tracked guidewire. An iterative-closest-point algorithm registered the position data to the preoperative image centerlines. To evaluate the registration accuracy, a guidewire was placed inside the superior mesenteric, left and right renal arteries under fluoroscopic guidance. Position data was acquired with electromagnetic tracking as the guidewire was pulled into the aorta. The resulting measured positions were compared to the corresponding ostia manually identified in the CTA images after applying the registration. The three-dimensional (3D) Euclidean distances were calculated between each corresponding ostial point, and the root mean square (RMS) was calculated for each registration. The median 3D RMS for all registrations was 4.82 mm, with an interquartile range of 3.53-6.14 mm. A vessel-based registration of CTA images to vascular anatomy is possible with acceptable accuracy and encourages further clinical testing. RELEVANCE STATEMENT: This study shows that the centerline algorithm can be used to register preoperative CTA images to vascular anatomy, with the potential to further reduce ionizing radiation exposure during vascular procedures. KEY POINTS: Preoperative images can be used to guide the procedure without ionizing intraoperative imaging. Preoperative imaging can be the only imaging modality used for guidance of vascular procedures. No need to use external fiducial markers to register/match images and spatial anatomy. Acceptable accuracy can be achieved for navigation in a preclinical setting.

Indexed as

AlgorithmsComputed Tomography AngiographyAnimalsCathetersElectromagnetic PhenomenaIliac ArteryRenal ArterySwineAortic aneurysm (abdominal)Computed tomography angiographyEndovascular proceduresRadiation exposureSurgical navigation systems

Identifiers

PMID39196294
PMCPMC11358569

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.