Evidence map›Paper›PMID 39194672›Full record

ArticleJournal of functional biomaterials2024

Mechanical Assessment of Denture Polymers Processing Technologies.

Cristina Modiga, Andreea Stoia, Marius Traian Leretter, Ana Codruţa Chiş, Andreea-Violeta Ardelean, Edward-Ronald Azar, Gabriel Kapor, Daniela-Maria Pop, Mihai Romînu, Cosmin Sinescu and 2 more

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Cristina ModigaDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.
Andreea StoiaDepartment of Mechanics and Strength of Materials, "Politehnica" University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timişoara, Romania.
Marius Traian LeretterDepartment of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Bd. Revolutiei din 1989, Nr. 9, 300041 Timişoara, Romania.
Ana Codruţa ChişResearch Institute for Biosafety and Bioengineering, The King Michael I University of Life Sciences, 119 Aradului Road, 300645 Timişoara, Romania.
Andreea-Violeta ArdeleanResearch Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.
Edward-Ronald AzarResearch Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.
Gabriel KaporDepartment of Mechanics and Strength of Materials, "Politehnica" University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timişoara, Romania.
Daniela-Maria PopDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.
Mihai RomînuDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.ORCID 0000-0003-1199-3020
Cosmin SinescuDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.
Meda-Lavinia NegruţiuDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.ORCID 0000-0002-1126-3944
Emanuela-Lidia PetrescuDepartment of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania.ORCID 0000-0002-0204-3026

Funding

Victor Babeș University of Medicine and Pharmacy Timișoara 16082/02.11.2018
6 · The paper itself

Abstract

backgroundRemovable prostheses have seen a fundamental change recently because of advances in polymer materials, allowing improved durability and performance. Despite these advancements, notable differences still occur amongst various polymer materials and processing technologies, requiring a thorough grasp of their mechanical, physical, and therapeutic implications. The compressive strength of dentures manufactured using various technologies will be investigated.

methodsTraditional, injection molding, and additive and subtractive CAD/CAM processing techniques, all utilizing Polymethyl methacrylate (PMMA) as the main material, were used to construct complete dentures. The specimens underwent a compressive mechanical test, which reveals the differences in compressive strength.

resultsAll the specimens broke under the influence of a certain force, rather than yielding through flow, as is characteristic for plastic materials. For each specimen, the maximum force (N) was recorded, as well as the breaking energy. The mean force required to break the dentures for each processing technology is as follows: 4.54 kN for traditional packing-press technique, 17.92 kN for the injection molding technique, 1.51 kN for the additive CAD/CAM dentures, and 5.9 kN for the subtractive CAD/CAM dentures.

conclusionsThe best results were obtained in the case of the thermoplastic injection system and the worst results were recorded in the case of 3D printed samples. Another important aspect depicted is the standard deviation for each group, which reveal a relatively unstable property for the thermoplastic injected dentures. Good results here in terms of absolute property and stability of the property can be conferred to CAD/CAM milled group.

Indexed as

3D printingdenture polymersmechanical testingpolymers injectionprocessing technologiessubstractiv CAD/CAM technique

Identifiers

PMID39194672
PMCPMC11355463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.