Evidence map›Paper›PMID 39192458›Full record

ArticleJournal of foot and ankle research2024

Comparison of accuracy and speed between plaster casting, high-cost and low-cost 3D scanners to capture foot, ankle and lower leg morphology of children requiring ankle-foot orthoses.

Muhannad Farhan, Joyce Zhanzi Wang, Rachael Warncke, Tegan Laura Cheng, Joshua Burns

Abstract readComparative Study
In one paragraph

Article in Journal of foot and ankle research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Muhannad FarhanUniversity of Sydney School of Health Sciences & Children's Hospital at Westmead, Sydney, New South Wales, Australia.
Joyce Zhanzi WangUniversity of Sydney School of Health Sciences & Children's Hospital at Westmead, Sydney, New South Wales, Australia.ORCID https://orcid.org/0000-0002-8336-5384
Rachael WarnckeOrthotics Department, The Children's Hospital at Westmead, Sydney, New South Wales, Australia.
Tegan Laura ChengUniversity of Sydney School of Health Sciences & Children's Hospital at Westmead, Sydney, New South Wales, Australia.ORCID https://orcid.org/0000-0002-4208-7242
Joshua BurnsUniversity of Sydney School of Health Sciences & Children's Hospital at Westmead, Sydney, New South Wales, Australia.ORCID https://orcid.org/0000-0001-7936-623X

Funding

Hyundai Help for KidsNational Health and Medical Research Council 1194930Saudi Arabian Cultural Mission
6 · The paper itself

Abstract

backgroundTraditional plaster-cast fabrication of an ankle-foot orthosis (AFO), although robust, is time-consuming and cumbersome. 3D scanning is quickly gaining attention as an alternative to plaster casting the foot and ankle region for AFO fabrication. The aim of this study was to assess the accuracy and speed of two high-performing 3D scanners compared with plaster casting in pediatric patients requiring an AFO.

methodsTen participants (mean age 10.0 ± 3.9 years) prescribed AFOs for a movement disorder were 3D scanned with the high-cost Artec Eva (Eva) and low-cost Structure Sensor II (SSII) using one-person (1p) and two-person (2p) protocols. Accuracy and speed for both 3D scanners were compared with corresponding plaster cast measures (≤5% acceptable difference). Bland and Altman plots were generated to show mean bias and limits of agreement.

resultsOverall, Eva and SSII were accurate for foot, ankle, and lower leg key clinical landmarks (Eva-1p: 4.4 ± 7.3%; Eva-2p: 3.2 ± 7.5%; SSII-1p: 0.6 ± 7.4%; SSII-2p: 0.7 ± 8.2%). Bland and Altman plots for the SSII demonstrated lower biases for 1p (bias 0.5 mm, LoA: -12.4-13.5 mm) and 2p (0.4 mm, LoA: -11.4-12.2 mm) protocols compared with Eva for 1p (bias 2.3 mm, LoA: -8.0-12.7 mm) and 2p (1.8 mm, LoA: -10.7-14.3 mm) protocols. The SSII 2p protocol was the fastest 3D scanning method (26.4 ± 11.1 s).

conclusionsThe high-cost Eva and low-cost SSII 3D scanners using the 1p and 2p protocols produced comparable accuracy and faster capture of key clinical landmarks compared with plaster cast measures for the fabrication of AFOs in pediatric patients.

Indexed as

AnkleCasts, SurgicalFootFoot OrthosesImaging, Three-DimensionalAdolescentChildFemaleHumansLegMale3D scanneraccuracyankle foot orthosisfoot measurement

Identifiers

PMID39192458
PMCPMC11349604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.