Evidence map›Paper›PMID 39192254›Full record

Trial reportBMC medical education2024

Comparison of AirAngel® vs. Storz® videolaryngoscope and Macintosh® laryngoscope for endotracheal intubation training: prospective randomized crossover study.

Şeyhmus Merter, Kamil Kayayurt, Dilek Kitapçıoğlu, Serpil Yaylaci

Abstract readRandomized Controlled TrialComparative Study
In one paragraph

Trial report in BMC medical education, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Şeyhmus MerterSchool of Medicine, Emergency Department, Acibadem Mehmet Ali Aydinlar University, Istanbul, 34457, Turkey.
Kamil KayayurtSchool of Medicine, Emergency Department, Acibadem Mehmet Ali Aydinlar University, Istanbul, 34457, Turkey. kamil.kayayurt@acibadem.edu.tr.
Dilek KitapçıoğluCenter of Advanced Simulation and Education, Acibadem Mehmet Ali Aydinlar University, Istanbul, 34457, Turkey.
Serpil YaylaciSchool of Medicine, Emergency Department, Acibadem Mehmet Ali Aydinlar University, Istanbul, 34457, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor both normal and difficult airway management, VL is thought to be more effective. However, VL seems far from being offered as a standard option in both healthcare delivery and educational activities in low-income countries, considering its high costs. Therefore, three-dimensional(3D)printed VLs may be considered an alternative to conventional VLs in low-income countries and other places with limited resources. Our objective was to compare the efficacy of AirAngel 3D-printed VL (3D-PVL) with those of commercially available Storz® VL (SVL) and conventional Macintosh® laryngoscope (MCL) in normal and difficult airway scenarios in the hands of inexperienced users.

methodsThis is a prospective randomized crossover manikin study that included 126 senior medical students with no experience in intubation. The effectiveness of all three laryngoscopy devices in the hands of inexperienced users was evaluated in terms of intubation time, glottic visualization, ease of use, endotracheal tube placement, and intubation success rate. Between 2020 and 2022, 126 last year medical students participated in the study.

resultsMCL resulted in significantly longer intubation times than 3D-PVL and SVL in the difficult airway scenario, with no significant difference between 3DPVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction MCL: 28.54 s; SVL: 26.68 s; 3DPVL: 26.64 s). Both SVL and 3D-PVL resulted in significantly better Cormack - Lehane grades in both normal and difficult airway scenarios, and thus provided better glottic viewing than MCL, with no significant difference between 3D-PVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction, MCL: 1.73; SVL: 1.29; 3DPVL: 1.25). The SVL was the easiest device to use for normal airway scenarios (1: very easy, 5: very difficult), while the MCL was the most difficult (MCL: 2.64; 3DPVL: 1.98; SVL: 1.49). Conversely, no significant difference was found between 3DPVL and other devices in terms of ease of use in difficult airway scenarios and in terms of accurate placement of the endotracheal tube and successful intubation attempts.

conclusion3D-PVL is a good educational and possible clinical alternative to conventional VL, particularly in places with limited resources, due to its low cost.

Indexed as

Cross-Over StudiesIntubation, IntratrachealLaryngoscopesLaryngoscopyManikinsClinical CompetenceEquipment DesignFemaleHumansMalePrinting, Three-DimensionalProspective StudiesStudents, Medical3D printingAirAngelIntubationMedical studentVideo laryngoscope

Identifiers

PMID39192254
PMCPMC11351083

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.