Evidence map›Paper›PMID 39191925›Full record

ArticleEvidence-based dentistry2024

Slow drilling technique may enhance peri-operative patient-reported outcomes in dental implant surgery.

Omer Waleed Majid

Abstract read
PubMed Publisher
In one paragraph

Article in Evidence-based dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Omer Waleed MajidProfessor, Department of Oral and Maxillofacial Surgery, College of Dentistry, Mosul University, Mosul, Iraq. omerwaleedmajid@uomosul.edu.iq.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designA randomized, controlled, single-blind clinical trial.

objectiveTo assess and compare patient-reported outcome measures (PROMs) between low-speed drilling without irrigation and high-speed drilling with irrigation for implant site preparation. PATIENTS AND

methodsThe study adhered to the Declaration of Helsinki principles, obtained approval from the local Ethics Committee, was registered on ClinicalTrials.gov, and was written in accordance with CONSORT guidelines. Included were adult patients with single posterior edentulism who exhibited good oral hygiene, sufficient bone dimensions for implant placement, adequate keratinized mucosa, stable occlusion, and a healthy periodontium. Patients were randomly assigned to either the test group (low-speed drilling (150 rpm) without irrigation) or the control group (high-speed drilling (800 rpm) with irrigation). A single dental implant was placed for each patient, with all surgeries conducted by the same experienced operator according to a standardized protocol. Patient satisfaction during surgery, including drilling-time perception, vibration, pressure, noise, comfort, and drowning sensation, as well as postoperative pain and inflammation, were assessed using a 100-mm visual analog scale. Quality of life (QOL) was evaluated using a 5-graded Likert scale for mouth opening, chewing, speaking, sleeping, daily routine, and job. Follow up extended on daily basis for 7 days. The PROMs were collected and analyzed in a blinded manner by independent researchers and a statistician to prevent bias.

resultsThe study included 66 patients (33 males and 33 females) with a mean age of 54.5 years. Patients in the test group reported a lower perception of drilling time, vibration, and noise but a higher perception of pressure compared to the control group; however, these differences were not statistically significant. Compared to the test group, patients in the control group experienced significantly greater drowning sensation and lesser comfort measures (p < 0.001). There was a moderate inverse correlation between drowning sensation and comfort (r = -0.57). The real drilling time was significantly longer in the test group compared to the control group (p < 0.001). The test group reported significantly lower pain levels during the first 12 h (p < 0.05), and significantly lower inflammation levels at the second day (p < 0.05) compared to the control group. No significant differences were observed between the groups at any time point for any of the QOL parameters (p > 0.05).

conclusionFor a single implant site preparation, low-speed drilling without irrigation seems to offer greater patient comfort compared to high-speed drilling with irrigation, mainly due to reduced drowning sensation. Patients reported less postoperative pain and inflammation with the low-speed technique. Confirming these findings will require more research.

Indexed as

Patient Reported Outcome MeasuresAdultAgedDental ImplantationDental Implantation, EndosseousFemaleHumansMaleMiddle AgedPatient SatisfactionQuality of LifeRandomized Controlled Trials as TopicSingle-Blind Method

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.