Evidence map›Paper›PMID 39190505›Full record

ArticleAnalytical chemistry2024

High-Resolution Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching.

Moritz Hitzemann, Ansgar T Kirk, Martin Lippmann, Alexander Nitschke, Olaf Burckhardt, Jonas Winkelholz, Stefan Zimmermann

Abstract read
In one paragraph

Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Moritz HitzemannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.ORCID 0000-0002-8950-8788
Ansgar T KirkInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.ORCID 0000-0001-7152-3077
Martin LippmannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.ORCID 0000-0003-3673-3030
Alexander NitschkeInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.ORCID 0000-0001-7144-9620
Olaf BurckhardtInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.
Jonas WinkelholzInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.
Stefan ZimmermannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.ORCID 0000-0002-1725-6657

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Besides safety and security applications, ion mobility spectrometry (IMS) is increasingly used in other fields such as medicine, environmental monitoring and food quality analysis. However, some applications require gas chromatographic separation before analysis by IMS. Furthermore, different compounds in the sample may form positive or negative ions during ionization and therefore simultaneous detection of both ion polarities is highly beneficial to avoid two chromatographic runs of the same sample. This can be achieved by ultra-fast polarity switching of a single drift tube IMS, allowing for quasi-simultaneous detection of both ion polarities. By using a ramped aperture voltage during the switching process, we overcome the issue of excessive displacement currents at the detector during polarity switching, which usually lead to overdriving the output signal of the high-gain transimpedance amplifier. Furthermore, mechanical aperture grid oscillations caused by polarity switching were also reduced through the ramped aperture voltage. This enables a polarity switching time of only 7 ms at a drift voltage of 8 kV and a drift length of 103 mm, leading to a high resolving power of

Identifiers

PMID39190505
PMCPMC11391402

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked