ArticleAnalytical chemistry2024
High-Resolution Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching.
Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Identification of Bacteria and Viruses by Pyrolysis-Gas Chromatography-Ion Mobility Spectrometry.Analytical chemistry · 2026Article
- Design and construction of a pyrolysis unit - demonstrated in connection with gas chromatography-ion mobility spectrometry.HardwareX · 2026Article
- How Repetition Rate Impacts Detection Limits of Ion Mobility Spectrometers with Field-Switching Ion Shutters.Analytical chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Besides safety and security applications, ion mobility spectrometry (IMS) is increasingly used in other fields such as medicine, environmental monitoring and food quality analysis. However, some applications require gas chromatographic separation before analysis by IMS. Furthermore, different compounds in the sample may form positive or negative ions during ionization and therefore simultaneous detection of both ion polarities is highly beneficial to avoid two chromatographic runs of the same sample. This can be achieved by ultra-fast polarity switching of a single drift tube IMS, allowing for quasi-simultaneous detection of both ion polarities. By using a ramped aperture voltage during the switching process, we overcome the issue of excessive displacement currents at the detector during polarity switching, which usually lead to overdriving the output signal of the high-gain transimpedance amplifier. Furthermore, mechanical aperture grid oscillations caused by polarity switching were also reduced through the ramped aperture voltage. This enables a polarity switching time of only 7 ms at a drift voltage of 8 kV and a drift length of 103 mm, leading to a high resolving power of
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.