ArticleJVS-vascular science2024
A porcine model of thoracic aortic aneurysms created with a retrievable drug infusion stent graft mirrors human aneurysm pathophysiology.
Article in JVS-vascular science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Objective: Aneurysm pathophysiology remains poorly understood, in part from the disparity of murine models with human physiology and the requirement for invasive aortic exposure to apply agents used to create aneurysm models. A retrievable drug infusion stent graft (RDIS) was developed to isolate the aortic wall intraluminally for drug exposure. We hypothesized that an RDIS could deliver aneurysm-promoting enzymes to create a porcine model of thoracic aneurysms without major surgical exposure. Methods: Retrievable nitinol stent graft frames were designed with an isolated drug delivery chamber, covered with polytetrafluoroethylene, and connected to a delivery wire with a drug infusion catheter installed to the outer chamber. Institutional Animal Care and Use Committee-approved Yorkshire pigs (n = 5) underwent percutaneous access of the femoral artery, baseline aortogram and stent placement in the thoracic aorta followed by 30-minute exposure to a cocktail of elastase, collagenase, and trypsin. After aspiration of excess drug, stent retrieval, and femoral artery repair, animals were recovered, with angiograms at 1 and 4 weeks followed by explant. Histological analysis, in situ zymography, and multiplex cytokine assays were performed. Results: The RDIS isolated a segment of anterior aorta angiographically, while the center lumen preserved distal perfusion during drug treatment (baseline femoral mean arterial pressure, 70 ± 14 mm Hg; after RDIS, 75 ± 12; Conclusions: An RDIS achieves isolated drug delivery while preserving distal perfusion to achieve an endovascular porcine model of thoracic aneurysms without major surgery. This model may have value for surgical training, device testing, and to better understand aneurysm pathogenesis. Most important, although the RDIS was used to simulate aortic pathology, this tool offers intriguing horizons for focused therapeutic drug delivery directly to aneurysms and, more broadly, focused locoregional drug delivery to vessels and vascular beds.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.