Evidence map›Paper›PMID 39188556›Full record

ReviewSmart medicine2023

Microfluidic preparation of optical sensors for biomedical applications.

Qiao Wang, Chong Wang, Xinyuan Yang, Jiali Wang, Zhuohao Zhang, Luoran Shang

Abstract readReview
In one paragraph

Review in Smart medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Cell-Based Immuno-Biosensors Using Microfluidics.Sensors (Basel, Switzerland) · 2026
    Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Review
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Qiao WangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.
Chong WangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.
Xinyuan YangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.
Jiali WangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.
Zhuohao ZhangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.
Luoran ShangShanghai Xuhui Central Hospital Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology) Institutes of Biomedical Sciences Fudan University Shanghai China.ORCID https://orcid.org/0000-0001-7458-9100

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical biosensors are platforms that translate biological information into detectable optical signals, and have extensive applications in various fields due to their characteristics of high sensitivity, high specificity, dynamic sensing, etc. The development of optical sensing materials is an important part of optical sensors. In this review, we emphasize the role of microfluidic technology in the preparation of optical sensing materials and the application of the derived optical sensors in the biomedical field. We first present some common optical sensing mechanisms and the functional responsive materials involved. Then, we describe the preparation of these sensing materials by microfluidics. Afterward, we enumerate the biomedical applications of these optical materials as biosensors in disease diagnosis, drug evaluation, and organ-on-a-chip. Finally, we discuss the challenges and prospects in this field.

Indexed as

disease diagnosisdrug evaluationmicrofluidicsoptical biosensororgan‐on‐a‐chip

Identifiers

PMID39188556
PMCPMC11235902

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.