Evidence map›Paper›PMID 39188085›Full record

ArticleMagnetic resonance in medicine2025

CineVN: Variational network reconstruction for rapid functional cardiac cine MRI.

Marc Vornehm, Jens Wetzl, Daniel Giese, Florian Fürnrohr, Jianing Pang, Kelvin Chow, Rolf Gebker, Rizwan Ahmad, Florian Knoll

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Multi-dynamic deep image prior for cardiac MRI.Magnetic resonance in medicine · 2025
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Marc VornehmDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0009-0004-5687-0563
Jens WetzlMagnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.ORCID 0000-0002-6484-2130
Daniel GieseMagnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.ORCID 0000-0002-3925-4441
Florian FürnrohrDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0009-0001-8013-1320
Jianing PangSiemens Medical Solutions USA Inc, Chicago, Illinois, USA.
Kelvin ChowSiemens Medical Solutions USA Inc, Chicago, Illinois, USA.ORCID 0000-0003-0698-1746
Rolf GebkerMVZ Diagnostikum Berlin 2020 GmbH, Berlin, Germany.
Rizwan AhmadBiomedical Engineering, The Ohio State University, Columbus, Ohio, USA.ORCID 0000-0002-5917-3788
Florian KnollDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0001-5357-8656

Funding

A comprehensive deep learning framework for MRI reconstructionR01EB029957 · NIBIB · OHIO STATE UNIVERSITY · PI AHMAD, RIZWAN, SCHNITER, PHILIP · 2021 to 2024
$2.3M
Erlangen National High Performance Computing Center b143dcNIBIB NIH HHS R01 EB029957NIBIB NIH HHS R01-EB029957Siemens Healthineers
6 · The paper itself

Abstract

purposeTo develop a reconstruction method for highly accelerated cardiac cine MRI with high spatiotemporal resolution and low temporal blurring, and to demonstrate accurate estimation of ventricular volumes and myocardial strain in healthy subjects and in patients.

methodsThe proposed method, called CineVN, employs a spatiotemporal Variational Network combined with conjugate gradient descent for optimized data consistency and improved image quality. The method is first evaluated on retrospectively undersampled cine MRI data in terms of image quality. Then, prospectively accelerated data are acquired in 18 healthy subjects both segmented over two heartbeats per slice as well as in real time with 1.6 mm isotropic resolution. Ventricular volumes and strain parameters are computed and compared to a compressed sensing reconstruction and to a conventional reference cine MRI acquisition. Lastly, the method is demonstrated in 46 patients and ventricular volumes and strain parameters are evaluated.

resultsCineVN outperformed compressed sensing in image quality metrics on retrospectively undersampled data. Functional parameters and myocardial strain were the most accurate for CineVN compared to two state-of-the-art compressed sensing methods.

conclusionDeep learning-based reconstruction using our proposed method enables accurate evaluation of cardiac function in real-time cine MRI with high spatiotemporal resolution. This has the potential to improve cardiac imaging particularly for patients with arrhythmia or impaired breath-hold capability.

Indexed as

AlgorithmsImage Processing, Computer-AssistedMagnetic Resonance Imaging, CineAdultDeep LearningFemaleHeartHeart VentriclesHumansImage Interpretation, Computer-AssistedMaleMiddle AgedRetrospective Studiescardiac imagingcine MRIdeep learningimage reconstructionvariational networkventricular function

Identifiers

PMID39188085
PMCPMC11518642

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.